Air inlet and exhaust kits.
The kits with relative accessories permit use of two concentric
systems.
As regards the load losses relating to each accessory and the
various possible combinations
see the instructions concerning
the air inlet and exhaust end pieces.
The coupling of the various accessories
(curves, extensions, end
pieces)
are of the push fitting and sealing is ensured by EPDM
peroxide lip seals resistant to the action of condensate.
80 /125 push fitting horizontal concentric kit.
The PPS exhaust pipe (80 mm Ø) is fitted inside the plastic
air inlet pipe (125 mm Ø).
Connection to the boiler is done using a concentric adapter
80/125 Ø (1) on which a 90° is fitted (4) adjustable in any di-
rection and which, with the necessary extensions, is connected
to the specific air inlet and exhaust end piece (5).
The overall maximum length permitted beyond the first curve
(4)
is 14 straight horizontal metres.
80 /125 push fitting vertical concentric kit.
The PPS exhaust pipe (80 mm Ø) is fitted inside the plastic
air inlet pipe (125 mm Ø).
Connection to the boiler is done using a concentric adapter
80/125 Ø (1). Any extensions needed are connected to the
specific air inlet and exhaust end piece 80/125 (7) with alu-
minium tile (5).
The overall maximum length permitted i
s 18 straight verti-
cal metres.
Inside the kit you will find:
No.1 - Adapter 80/125 Ø (1)
No.1 - Seal (2)
No.1 - Concentric curve 80/125 Ø at 87° (4)
No.1 - Concentric air inlet/exhaust end piece 80/125 Ø (5)
No.1 - Internal washer (6)
No.1 - External washer (7)
2
1
3
4
7
5
6
Inside the kit you will find:
No.1 - Adapter 80/125 Ø (1)
No.1 - Seal (2)
No.1 - Washer (4)
No.1 - Aluminium tile (5)
No.1 - Fixed half shell (6)
No.1 - Concentric air inlet/exhaust end piece 80/125 Ø (7)
No.1 - Moveable half shell (8)
2
1
3
4
5
8
7
6