Selenio X100
Installation and Operation Manual
71
ii.
Trigger
to the desired value (options are
RisingEdge, FallingEdge, ActiveHigh
and
ActiveLow
)
2
Configure the BT-1685 inserter
to insert BT-1685 packets on line 12 of video output 1:
a
Go to
Video > Video Output and Routing > Proc Ch 1 Out Format
and then select
1080i/59.94
.
b
At
Data > Output > Proc Ch 1 Output > Proc Ch 1 LN 12
, select
Trigger BT1685.
c
Go to
Data > Advanced Status and Control > BT-1685 > GPI Input to VANC
to
configure the DID, output stream and output field for the embedded BT-1685 packets.
3
Generate GPI pulses to all GPI inputs.
BT-1685 packets will now be visible, embedded in the VANC region on line 12 with the
trigger bits
Q1-Q8
toggling between
0xFF
and
0x00
at the incoming GPI pulse rate.
BT-1685 Extraction Setup Example
This example involves extracting BT-1685 packets from line 12 and inserting on GPI outputs.
1
Connect the video signal with embedded BT-1685 packets to the video input (for example,
video input 1).
2
Configure the BT-1685 extractor to extract BT-1685 packets on line 12 of video input 1:
a
Go to
Data > Advanced Status and Control > BT-1685 > VANC to GPI Output
and
then configure the DID and set the
BT1685 Input Line Mode
to
Fixed.
b
Go to
Data > Advanced Status and Control > BT-1685 > VANC to GPI Output >
From Channel 1
and then set the
Channel 1 BT1685 Input Line
to
12.
c
Confirm that
Data > Advanced Status and Control > BT-1685 > VANC to GPI
Output > From Channel 1
is set to
Channel 1 BT1685 Input Present > Yes.
3
Configure the GPI outputs for channel 1 BT1685 extraction:
a
At
GPI and Rules Engine > GPI > GPI Direction
, set all eight
GPIO Directions
to
Output.
b
At
GPI and Rules Engine > GPI > GPI Output
, for each
GPI Output To Edit (GPIO 0
to
GPIO 7
), set
Event
to
SCTE104/BT1685 Control.
c
Go to
GPI and Rules Engine > GPI > GPI Output > SCTE104/BT1685 GPI Out
Processing
and then set
GPI Delay & Hold Processing Mode
to
Bypass.
d
At
GPI and Rules Engine > GPI > GPI Output >
set
GPI Data Type
to
Proc Ch 1
BT1685.
e
Go to
GPI and Rules Engine > GPI > GPI Output > GPI Level Invert
and then set the
level accordingly.
From the GPI outputs, observe the state of the 8 GPI outputs, following trigger bits
Q1
-
Q8
extracted from the incoming BT-1685 packets.
AFD, VI and WSS
The X100 can handle single data passing, filling, replacing, data based arcing, multiple data
crossing, and translating. The related controls are located at
Video > Processing Channel
> Conversion and Advanced Video Processing
.
Содержание Selenio X100
Страница 8: ...Selenio X100 Installation and Operation Manual viii...
Страница 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Страница 22: ...Selenio X100 Installation and Operation Manual 10...
Страница 38: ...Selenio X100 Installation 26...
Страница 158: ...Appendix A Laser Safety Guidelines 146...
Страница 178: ...166...