Selenio X100
Installation and Operation Manual
119
Loudness Control Parameters
Table 4-10.
DTS Neural Audio Loudness Control Parameters
Parameter Name
Function
Options
Loudness Control Function
Enables the Loudness Control feature
Enable
Disable
Loudness Control Status
Indicates the state of the AAP mode
Uninitialized
Running
Not Running (bypassed)
Not Running
Target Loudness Level
Specifies the loudness level that will be targeted
-40 dBEq to 0 dBEq
(
-27 dBEq
)
LC Ratio
Controls the amount of gain or attenuation that is
applied when loudness differences are measured
0% to 100% (
90%
)
Upper Threshold
Specifies the highest measured loudness of the
input that will be permitted before attenuation is
applied
0 dB
to 20 dB
Lower Threshold
Specifies the lowest measured loudness of the input
that will be permitted before gain is applied
-20 dB to
0 dB
Freeze Window
Specifies the size of a window in which small
loudness differences are allowed without the need
to change gain or attenuation
0.0 dB to 10.0 dB (
1.0 dB
)
Quiet Threshold
Controls the noise floor level
-80 dBEq to -20 dBEq
(
-50 dBEq
)
Attack Time
Controls how quickly the processing will respond to
sharp increases in loudness
5 ms to 150 ms (
20 ms
)
Release Time
Controls how quickly the processing will respond to
sharp decreases in loudness
20 ms to 500 ms (
120 ms
)
Compressor Threshold
Controls the amount of attenuation applied when
short-term peaks exceed the compressor threshold
0 dB to 16 dB (
5 dB
)
Compressor Ratio
Controls the amount of attenuation applied when
short-term peaks exceed the compressor threshold
0% to 100% (
40%
)
Loudness Shaping
Specifies the amount of loudness shaping desired
0.0 to 1.0 (
0.5
)
Final Limiter Ceiling
Specifies the threshold above which final limiting
will be applied
-20 dBFS to 0 dBFS (
0 dBFS
)
Metering
Activates the real-time meter.
Off
On
Current Input Loudness
[RO]
Reports the smoothed input loudness measurement -60 dBEq to 20 dBEq
(
0 dBEq
)
Current Input Peak [RO]
Reports the input peak measurement
-60 dBFS to 20 dBFS (
0 dBFS
)
Current Output Loudness
[RO]
Reports the smoothed output loudness
measurement
-60 dBEq to 20 dBEq
(
0 dBEq
)
Current Output Peak [RO]
Reports the output peak measurement
-60 dBFS to 20 dBFS (
0 dBFS
)
Current Correction [RO]
Reports the amount of correction being applied
-60 dB to 60 dB (
0 dB
)
Current Compression [RO]
Reports the amount of compression being applied
-60 dB to 60 dB (
0 dB
)
Содержание Selenio X100
Страница 8: ...Selenio X100 Installation and Operation Manual viii...
Страница 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Страница 22: ...Selenio X100 Installation and Operation Manual 10...
Страница 38: ...Selenio X100 Installation 26...
Страница 158: ...Appendix A Laser Safety Guidelines 146...
Страница 178: ...166...