Scalar Configuration
These parameters provide a number of controls to optimize your custom ARC settings.
Scalar Config
Fill Color
sets the background color that may appear around the perimeter of a scaled
image. Options are:
Black (default)
Super-Black
Red 50%
Green 50%
Blue 50%
Orange 50%
Grey 50%
Grey 40%
Grey 25%
Vertical and Horizontal Bandwidth
These two parameters adjust bandwidth for the scalar in a range from
-50
to
50
(default is
0
).
NR Enable, Mosquito NR, Block Artifact NR, and Noise Reduction
NR Enable
activates all of the noise reduction parameters (default option is
No)
.
Mosquito NR
reduces the “buzzy” edges that may be seen when video has passed
through the MPEG compression/decompression (encode/decode) process.
Similarly, the
Block Artifact NR
reduces “cockiness” that may be seen when video has
passed through the MPEG compression/decompression (encode/decode) process.
Noise Reduction
controls the total amount of all noise reduction controls (picture may
become softer as this is increased).
All of these parameters have a scale of
0
to 1
000
; the default is
0
.
Sharpness Level and Sharpness Overshoot
The
Sharpness Level
parameter is used in conjunction with the
Noise Reduction
control
to provide enhancement on large edges.
Sharpness Overshoot
is used in conjunction with the
Sharpness Level
control for
enhancement of large edges.
Содержание Selenio X100
Страница 8: ...Selenio X100 Installation and Operation Manual viii...
Страница 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Страница 22: ...Selenio X100 Installation and Operation Manual 10...
Страница 38: ...Selenio X100 Installation 26...
Страница 158: ...Appendix A Laser Safety Guidelines 146...
Страница 178: ...166...