31
QUALIFIED INSTALLER
The hobs are delivered to operate as indicated on the data plate. If a transfor-
mation should be necessary, proceed as described in the next paragraph.
Injector replacement and air adjustment for models:
H30 - H360 - H380 - H39 - HF40 - HP45F - HP65 - HP75 - HP95 - HAP95 - XLP90F-
HP1230 HP125 - HAP125 - HP665 - HP965 - HP1265 - HP90 - HP120
1. Remove the grill and the burners from the worktop.
2. Unscrew the screws marked with the arrows that fix the worktop to allow it to
be raised, pic. 5, pic. 5a, pic. 5b.
3. Unscrew venture pipe screw “F” (pic. 6, pic. 7) and open completely the air
regulator “R”.
4. Unscrew the injectors (U) and replace them with those suitable for the gas in
use and supplied with the appliance. Refer to table on page 33.
5. Air adjustment is made by the special regulator “R” based on the “X” values
shown in table on page 33, opening of primary air. When adjustment is over
block the regulator “R” with screw “F”.
Adjustment and/or
adapting to different
types of gas
Pic. 5
Pic. 5a
INSTALLATION
Adjustment and/or adapting to different types of gas