ITW Dynatec
Chapter 5
Maintenance and Repair Notes
Page 46
Apex Slot Die Applicator, Manual #40-47, Rev. 10.16
21. Re-install a new filter basket and
the filter nut.
Tighten the filter nut until it is
seated firmly, taking care not to
cut the O-ring.
After finishing the maintenance or repair works:
Remove all materials and tools used during the repair or maintenance from the
workspace of the unit.
Connect the voltage supply and the compressed air supply. Heat the unit up. Wait until
all temperatures are within the tolerances and the adhesive in the hopper is molten
completely.
Continue production.