Chapter 5
Maintenance and Repair Notes
ITW Dynatec
Apex Slot Die Applicator, Manual #40-47, Rev. 10.16
Page 45
5.4 Replacement of the Filter in Optional Filter Block
WARNING
Heed all security advices given in chapter 5.1.
Maintenance and repair work is only permitted for skilled personnel!
Always wear safety shoes, heat-resistant protective gloves, safety goggles
and protective clothing that cover all vulnerable parts of the body while
working on the heated unit! Risk of injury or severe burns!
During this procedure, hot adhesive can come out of the Applicator
under high pressure.
Components and adhesive are hot when this procedure is being done.
Take every precaution to prevent the material and hot surfaces from
contacting the skin.
NOTE: To make filter access easier, the filter block may be rotated 180°.
11. The Applicator must be at operating temperature.
12. Turn the ASU’s pump/ motor OFF.
13. Switch the unit voltage-free and pressureless.
14. Guard the unit against unauthorized restarting.
15. Place a heat-resistant catchment container/underlay under the Applicator.
Hot adhesive may come out!
16.
Relieve the adhesive pressure by
:
a. Manually open the module(s).
This is done by pushing the
solenoid operator button(s)
located on the back of the air
solenoid coil(s).
b. Open the purge screw two
turns. This screw is located on
the back of the filter block next
to the tamper-proof screw
which prevents its removal.
c. If the ASU filter manifold is
equipped with a drain,
adhesive pressure may be
relieved at the ASU.
17. Wearing insulated gloves,
unscrew and remove the filter nut.
18. With needle nose pliers, pull the
old filter basket out of the filter
block.
19. Replace the O-ring on the filter
nut. Apply O-ring lubricant (PN
N07588) to the new O-ring.
20. Apply a coat of anti-seize to the
threads of the filter nut.
Back of Filter Block
(* two module/solenoid model shown)
Filter Nut
Purge Screw
Filter Block Drain
Solenoid Operator
Buttons (2*)
O-ring
Filter
Basket
Filter
Nut