installed across the 12V power lines to the iGuard. Refer to the Connection Diagram in
the Appendix for more information.
Warning
: Use ONLY the power supply provided. Do not use other power supplies since
this may lead to system failure, and poor or unreliable operation.
When deciding where to install
…
iGuard is a wall-mounted unit with a miniscule footprint, and can be conveniently installed
anywhere. However, for
access control
applications, it is recommended that the iGuard
should be installed as close to the door as possible, so that the user can open the door
within the timeout period, which is 5 seconds by default. Also note the following points:
Make sure that air can circulate freely through the ventilation slots.
Do not install the product next to heat-emitting sources, or in a place subject to
direct sunlight and excessive dust.
Connect the Power & External Controls
iGuard provides easy-access terminals for connections to external controls, including Door
Strikes, Door Sensor and External Alarm.
Terminals
Description
Power
Power (12V DC)
The power requirement is 12V DC, 800mA. Connect it to the
power supply provided.