– iGuard Information
Terminal ID
– Assign an ID to the unit. In a Master / Slave configuration, this Terminal ID
is used to identify each slave unit in the network. Identical ID can be assigned to different
iGuards. However, it is suggested to assign unique ID to each iGuard in a Master / Slave
configuration, to avoid confusion when assigning departments’ access right, in which the
Terminal ID is used to identify which iGuard in the network is accessible by the
department’s members.
Description
– Assign a descriptive name to the unit, for displaying in the “Terminal List”
page.
Company Code
– This is applicable for Smart Card operation only, when the
Smart Card
Mode
is set to “Full Read/Write” mode. This Code is a 4-character string that will be
written to the smartcards issued by the unit. When reading the card, iGuard will first
compare the smartcard’s code against the device’s code. If they do not match, iGuard will
just simply ignore the card.
The default is “CMPY”.
The
Smart Card Mode
can be configured in the same setup page, and will be discussed
later (page 54).
Warning
: This value must be set prior to issuing any smartcard, and must not be changed
afterwards. Otherwise, all previously issued smartcards will be ignored.
Basic
– Peripheral
This is for setting up the optional
Remote Door Relay
, which is a small device for
controlling the electric door strike.
Normally, the electric door strike is connected directly to the built-in door relay of the
device. For higher security purpose, this Remote Door Relay can be used instead of the
built-in one to control the door strike, to avoid the possible intruder break-in by opening the
iGuard and directly shorting the door strike wires.
More details will be discussed in the Appendix (page 67).
Enable Remote Door Relay
– Enable this if the optional Remote Door Relay is available.
Remote Relay ID
– This number must match the 8-bit jumper block setting located on
Remote Door Relay device.
Basic
– System
1
st
day of the week
– Use this to change the first day of the week from the default Sunday
to others (useful for some Muslim countries and Hispanic).
Report Date Format
– Select the desired date format from the list. Available date formats
are MM/DD/YYYY, MM-DD-YYYY, DD/MM/YYYY and more.
Содержание LM530
Страница 1: ......
Страница 71: ...iGuard LM530 Operation Manual Version 1 0 66 4 Employee Profile...
Страница 75: ...iGuard LM530 Operation Manual Version 1 0 70 Connection Diagram Basic Connection...
Страница 76: ...iGuard LM530 Operation Manual Version 1 0 71 Basic Connection Large Load...
Страница 77: ...iGuard LM530 Operation Manual Version 1 0 72 Remote Relay...