Operating instructions AX460
25
Operating mode
Totalizer
INPUT 1 TOTAL
INPUT 2 TOTAL
LINKAGE TOTAL
IN 1 + IN 2
active
active
Total 1 + Total 2
IN 1 - IN 2
active
active
Total 1 - Total 2
IN 1 x IN 2
active
active
→ 0
IN 1 / IN 2
active
active
→ 0
TIME BASE
This parameter defines the time base for the totalization� It indicates the time interval for the detection of
the measured values�
SECONDS
The current value is added to INPUT 1 TOTAL every second
MINUTES
The current value is added to INPUT 1 TOTAL every minute
HOURS
The current value is added to INPUT 1 TOTAL every hour
COMMAND
The current value of input 1 is added to INPUT 1 TOTAL by means of
the command (ADD TO
TOTAL 1) via the operation function of a control input
DIVIDER
This parameter defines the divisor for the totalization�
1
No division
10
Result of the totalization is divided by 10�
100
Result of the totalization is divided by 100�
1000
Result of the totalization is divided by 1000�
DECIMAL POINT
This setting defines the position of the decimal point�
NO
No decimal point
0000000�0
Decimal point at the specified spot
000000�00
Decimal point at the specified spot
00000�000
Decimal point at the specified spot
0000�0000
Decimal point at the specified spot
000�00000
Decimal point at the specified spot
00�000000
Decimal point at the specified spot
0�0000000
Decimal point at the specified spot
SCALE UNITS