RESULT=PRES
Display value equal to preselection 1� In combination with hysteresis 1
a frequency band (presel/- ½ hysteresis) can be defined and
monitored�
With hysteresis 1 not equal to 0 the following switching condition
results:
Display value > preselection 1 + ½ hysteresis 1 → OFF
Display value < preselection 1 - ½ hysteresis 1 → OFF
RES≥PRES-TRAIL
Tracking preset 1:
Display value greater or equal to preselection 2 – preselection 1
Preselection 1 is the tracking preset of preselection 2�
HYSTERESIS 1
Hysteresis to define the switch-off point for the switching condition of preselection 1
0
No switching hysteresis
…
99999
Switching hysteresis of 99999
PULSE TIME 1 (S)
Duration of the fleeting pulse (in seconds) for the switching condition of preselection 1
0,000
No fleeting pulse (static signal)
…
60,000
Pulse duration of 60 seconds
OUTPUT TARGET 1
Assignment of an output for the switching condition of preselection 1�
If several switching conditions are assigned to one single output, this output is active as soon as one of the
switching conditions is met�
NO
No attribution
CTRL OUT 1
Assignment of the switching condition to Ctrl� Out 1
CTRL OUT 2
Assignment of the switching condition to Ctrl� Out 2
CTRL OUT 3
Assignment of the switching condition to Ctrl� Out 3
CTRL OUT 4
Assignment of the switching condition to Ctrl� Out 4
OUTPUT POLARITY 1
Start-up delay for the switching condition of preselection 1
ACTIVE HIGH
Active "HIGH"
ACTIVE LOW
Active "LOW"
OUTPUT LOCK 1
Start-up delay for the switching condition of preselection 1
NO
No latching
YES
Latching