OSC messages: Local inputs/outputs (safety)
42326
Message
Type
Corrective measures
Test signal for cross-fault monitoring cannot be
detected: currDev=%s; currDiagState=%s;
prevDiagState=%s; addr1=%s; addr2=%s
Error
► Check settings of the parameter of the logical
"SF_local_testpulse"
Cross fault on a safe input: currDev=%s;
currDiagState=%s; prevDiagState=%s;
addr1=%s; addr2=%s
Error
► Check connection to local device.
CODESYS: dynamic parameter "IN_Channel"
on FB "GetLocal...": currDev=%s;
currDiagState=%s; prevDiagState=%s;
addr1=%s; addr2=%s
Error
► Check setting of the parameter "IN_Channel" on FB.
CODESYS: "local_IO" Channel A = 0:
currDev=%s; currDiagState=%s;
prevDiagState=%s; addr1=%s; addr2=%s
Error
► Check setting of the parameter "Channel A" an the logical
device.
CODESYS: "local_IO" Channel B = 0:
currDev=%s; currDiagState=%s;
prevDiagState=%s; addr1=%s; addr2=%s
Error
► Check setting of the parameter "Channel B" on the logical
device.
CODESYS: "local_IO" Channel A = Channel B:
currDev=%s; currDiagState=%s;
prevDiagState=%s; addr1=%s; addr2=%s
Error
► Check setting of the parameter "Channel A" and
"Channel B" on the logical device.
CODESYS: "local_IO" multiple use of a channel
in the configuration: currDev=%s;
currDiagState=%s; prevDiagState=%s;
addr1=%s; addr2=%s
Error
► Check channel use in the configuration.
CODESYS: simultaneous use of a channel as
safe and non-safe information: currDev=%s;
currDiagState=%s; prevDiagState=%s;
addr1=%s; addr2=%s
Error
► Check channel use in the configuration.
CODESYS: FB parameter "IN_Channel_X"
refers to a non-configured safe local input:
currDev=%s; currDiagState=%s;
prevDiagState=%s; addr1=%s; addr2=%s
Error
► Check channel use in the configuration.
>
OSC messages: FSoE (Safety)
42319
Message
Type
Corrective measures
BIT_FSOE_CONNETION_LOSS_WARN_2:
Param1: Connection ID, Param2: DiagCode
(FSOE)
Warning
► Check FSoE connection
BIT_FSOE_CONNECTION_ESTABLISHED_1:
Param1: Connection ID
Note
FSoE connection established