SmartPLC SafeLine with PROFIBUS slave interface
207
Comm. no.
[hex]
Comm. no.
[dec]
Description
Note
004C
76
CTT2 device group selective write from buffer:
device group read / write call of an AS-i slave with CTT2 profile
CTT2 slave profile *)
0050
80
set AS-i master settings
0051
81
Reset the error counters
Legend:
*) ... CTT2 profiles = S-7.5.5, S-7.A.5 or S-B.A.5
CTT
→
Combined transaction – Use of analogue channels in the gateway depending on the slave profile
(
→ S.
Detailed information about the acyclic data sets and the command interface is given in the
supplement to the device manual of the SmartSPS SafeLine mit Profibus-Slave-Schnittstelle
(
→
Overview: User documentation for AC4S
(