5
• Installation, electrical connection, set-up, programming, configuration, operation
and maintenance of the product must be carried out by personnel qualified and
authorised for the respective activity�
• Protect units and cables against damage�
• The unit may cause radio interference in domestic areas� If interference occurs,
the user must take appropriate remedial actions�
• The unit complies with the standard EN 61000-6-4 and is a class A product�
The radiated energy of the microwaves is, for example, much below that of
mobile phones� According to the current state of science the operation of the
unit can be classified to be harmless to human health�
3 Items supplied
• Level sensor LR8300
• Operating instructions
In addition, the following is necessary for installation and operation:
• 1 rod
• mounting material (if necessary, a launching plate
→ 4.1
)
The following components are available as accessories:
Rods
Length (cm / inch)
Order number
15 / 5�9
E43225
24 / 9�5
E43203
30 / 11�8
E43226
45 / 17�7
E43204
50 / 19�7
E43227
70 / 27�6
E43205
100 / 39�4
E43207
120 / 47�2
E43208
140 / 55�1
E43209
160 / 63�0
E43210
Flange plate
Size / process connection
Order number
73 - 90 / ¾” NPT
E43206
Only use rods from ifm electronic gmbh� The optimum function is not
ensured when using components from other manufacturers�