3 - INFORMATION FOR SET UP
KID 80 SIV
EN
3 - Pag. 9 / 26
no. 60 First feeding value (B)
This parameter value should be entered.
This is the value of the first feeding
stroke, that is the distance between the
front edges of the first feeding carriage in
"After removal movement" and "first
feeding limit switch" position (point B).
no. 61 Feeding value (x)
This is the stroke value for the bar
loading into the bar pusher collet.
60
no. 60 First feeding
value (B)
XXXX (mm)
(inches)
DEFAULT VALUE
PROGRAMMABLE
VALUE
K I D
K I D
1720
2070
61
no. 61 Feeding
value (x)
XXXX (mm)
(inches)
DEFAULT VALUE
PROGRAMMABLE
VALUE
K I D
K I D
0
2070