EN
2 - INFORMATION FOR USE
KID 80 SIV
2 - Pag. 62 / 66
18 - FAILURE DURING THE BAR CHANGE
Warning: THE BAR CHANGE WAS NOT COMPLETED IN THE PRESET TIME.
CAUSE SOLUTION
18
18 Failure during
the bar change
When an unforeseen mechanical or
electrical error occurs, a safety time
stops the machine if the bar change
cycle does not occur in the preset
time.
Check the exact cause of the fault and
reset the working cycle.
19 - NO BAR
IN AUTOMATIC MODE, THE MECHANICAL FEEDING IS ACTIVATED BUT ITS PROCEDURE HAS
NOT BEEN COMPLETED AND THE COMPLETELY CLOSED CLAMP SENSOR IS ON.
CAUSE SOLUTION
19
19 No bar
The phase detector is not working
properly.
Make sure that the phase detector on
the mechanical cam works properly
There is a mechanical obstacle
22 - MACHINE OK!
THIS IS A MESSAGE AND DOES NOT NEED A RESET. IT IS USED ONLY TO SEND AN SMS OR AN
EMAIL INFORMING ON THE AUTOMATIC RESET AFTER AN ALARM.
CAUSE SOLUTION
22
22 Machine OK!
This message appears for a few
seconds when the bar feeder is in
automatic mode and the error has
been eliminated.
Example: after resetting the emergency
mushroom-head button.
INFORMATION:
This message is used to send an sms or an email informing on the automatic
reset after an alarm. It can only be used by customers with IT infrastructures
that allow the connection of IEMCA bar feeder to the corporate network.
Содержание KID 80
Страница 2: ......
Страница 4: ......
Страница 11: ...1 BASE INFORMATION KID 80 SIV EN 1 Pag 5 15 ...
Страница 22: ......
Страница 28: ...EN 2 INFORMATION FOR USE KID 80 SIV 2 Pag 6 66 3 press the bar feeder performs the second step and so on ...
Страница 105: ...3 INFORMATION FOR SET UP KID 80 SIV EN 3 Pag 17 26 ...
Страница 114: ...EN 3 INFORMATION FOR SET UP KID 80 SIV 3 Pag 26 26 ...