2 - INFORMATION FOR USE
KID 80 SIV
EN
2 - Pag. 63 / 66
24 - THREAD SAFETY
Warning: THE LATHE HAS NOT CARRIED OUT THE THREADING OPERATION ON THE PIECE TO
BE MACHINED.
CAUSE SOLUTION
24
24 Error: thread
safety
Threading device failure.
Check the effective functioning of the
lathe device.
Threading controlling device failure. Check the microswitch placed on the
cam box of the thread safety.
The bar did not move to the last
"COLLET OPENING".
Make sure that the lathe collet opens
correctly and check the bar feeder
thrust (parameter 34).
25 - CARRY OUT THE 0-AXIS AFTER A POWER OFF-ON
THE ENCODER VALUE PRESET OPERATION WAS NOT CARRIED OUT CORRECTLY IN THE PRESET
TIME.
CAUSE SOLUTION
25
25 Carry out 0-axis
after a power off-on
The PLC and drive connection cable
is broken.
Contact Iemca service department.
The drive is faulty.
Содержание KID 80
Страница 2: ......
Страница 4: ......
Страница 11: ...1 BASE INFORMATION KID 80 SIV EN 1 Pag 5 15 ...
Страница 22: ......
Страница 28: ...EN 2 INFORMATION FOR USE KID 80 SIV 2 Pag 6 66 3 press the bar feeder performs the second step and so on ...
Страница 105: ...3 INFORMATION FOR SET UP KID 80 SIV EN 3 Pag 17 26 ...
Страница 114: ...EN 3 INFORMATION FOR SET UP KID 80 SIV 3 Pag 26 26 ...