no. 78 Toque reduction during
bar change
Defines the torque value by which the
bar pusher moves during the bar
change cycle in the phases described
by B, C, D, E subparameters. This
value is expressed as a percentage of
the maximum torque.
Parameter:
A - Torque reduction during bar
change
Subparameters:
B - From collet entry slowdown to
pulse window end
C - Pulse backwards
D - Facing to limit stop
E - Facing jog
78
no. 78 Torque
reduction
during bar change
DEFAULT VALUE
PROGRAMMABLE
VALUE
KID
KID
A
/ 0÷100
B
40 0÷100
C
100 0÷100
D
35 0÷100
E
50 0÷100