Setting Changes
p.53
2.1
Time Schedule
You can define up to 10 time schedule codes. Time schedule code 00 is the default code an
d can be used to allow round-the-clock access. You can define time schedule codes 01 to 10.
Each time schedule code has 8 programmable days (i.e. Sun, Mon, Tue, Wed, Thu, Fri, Sat a
nd holiday) and each day has 5 time intervals.
How to Define Time Schedule Codes
To define a new T/S code or change an existing one, press <ENT>, and the LCD will
show T/S information such as T/S code, day, ti7me interval and time period. Press
<2> or <8> to scroll up or down the time schedule code (01-10) and the day of the
week. (Mon - Sun and holiday). Press <4> or <6> to scroll up or down the time inte
rval. The holiday in this time schedule will be linked to the holiday schedule code. S
elect a time schedule code, day and Interval, and press <ENT>. Enter the start and
end time for the time interval in the 24-hour, hh/mm format, then press <ENT> to
save the new T/S settings. Once all information is entered, press <ESC> to return to