background image

 
 
                                                                                                                 

   

 

49

 

16. Template 

 

 

Содержание Star FINGER006

Страница 1: ...User s Manual Fingerprint Identification Proximity PIN Reader...

Страница 2: ...e 14 7 2 Check Point during Installation 15 7 2 1 Termination Resistor 15 7 2 2 How to Connect Termination Resistors 15 7 2 3 Grounding System for Communication Cable 16 8 Installation of the Product...

Страница 3: ...ION 29 12 1 8 CARD ID CLEAR 30 12 1 9 EVENT CLEAR 30 12 2 SETUP MENU F2 31 12 2 1 LCD DISPLAY 32 12 2 2 BUZZER STATUS 32 12 2 3 OUTPUT MODE 32 12 2 4 LED_BUZZER_CONTROL 32 12 2 5 RF PIN INPUT 33 12 2...

Страница 4: ...FP STATUS 44 12 4 13 HIGH SECURITY 44 12 4 14 FP QUALITY 45 12 4 15 FP LEVEL 45 12 4 16 FINGERPRINT MODULE VERSION 45 12 4 17 FINGERPRINT COUNT 45 12 4 18 FINGERPRINT MODULE TEST 46 12 4 19 FINGERPRI...

Страница 5: ...uit parts possibly resulting in fire or electric shock Never spill liquid of any kind on the product 7 Never disassemble this product by yourself take the unit to a qualified service center whenever s...

Страница 6: ...ination of Proximity PIN and Biometric may be used and different verification levels can be customer programmed for each user or user group 3 Features 125KHz Proximity PIN and Fingerprint Recognition...

Страница 7: ...Flash Memory Fingerprint User 1 000 2 000 4 000 Fingerprint Users Fingerprint Template Size 800 Bytes for 2 Fingerprint Templates Read Range Passive Type IDK50 IMC125 Up to 2 inch 5cm IDC80 IDC170 Up...

Страница 8: ...umidity Non Condensing Color Material Dark Pearl Gray Polycarbonate Dimension W x H x T 161 5mm x 134mm x 48 5mm 6 36 x 5 28 x 1 9 Weight 547g 1 21lbs Certification MIC Fingerprint Module Specificatio...

Страница 9: ...failure Keypad Registration The built in keypad and the LCD screen let you perform manual programming without a PC connected Dual Finger Mode Dual Finger Mode is a function that lets a user register...

Страница 10: ...ly 6 2 Product Explanation 6 2 1 Panel Description Front View LCD Display LCD displays FINGER006 s status 3 LED Indicators showing system status The red LED turns on with power supply The green LED tu...

Страница 11: ...will turn on But in the collision status 2 LED red will turn on Figure The Communication Display LED in the Rear View 6 2 2 Color Coded Wiring Table I O PORT NAME SIGNAL NAME COLOR CODED POWER CON7 M...

Страница 12: ...White TTL Output2 TTL2 D1 Brown with White Stripe OK Signal Out OK Out Not Use Green with Red Stripe Error Signal Out Error Out Not Use Blue with Red Stripe Tamper Switch Out Tamper Switch Out Not Use...

Страница 13: ...d with common hand tools and readily available communications wires This section provides information about wiring wire runs and other information to make the installation quick and easy 7 1 Check Poi...

Страница 14: ...shielded 300m Belden 9514 22 AWG 8 conductor shielded Door Lock Alarm Device Lock Alarm Controller Belden 9409 18AWG 2 conductor unshielded 300m RS232 Cable Belden 9829 24 AWG 2 twisted pair shielded...

Страница 15: ...ter the leading edge of a bit Since the data bit is captured in the middle of the bit which is approximately 52us after the leading edge of a bit The reflection stabilizing time 18 6us is much before...

Страница 16: ...re when the voltage level of both ends of shield wire is not equal and this current flow will create noise and interfere to communications For the good grounding we recommend to connecting ONLY one en...

Страница 17: ...Wall Mount as indicated then run the cable from the main unit through the center hole and snap in place the main unit to Wall Mount Make sure that the main unit is secure locked in place with Wall Mo...

Страница 18: ...switch in the back of the FINGER006 unit If you want hardware initialization press key 1 otherwise press key 0 1 Press the key 1 if you wish to initialize the FINGER006 2 Initialization is progressing...

Страница 19: ...the controller to OK Signal In wire Green Connect Tamper input wire of the controller to Tamper Switch Out wire Yellow with White stripe External Reader Connection Wiegand Input Connect Data 0 wire of...

Страница 20: ...FINGER006 to RS422 TX port of the converter Plug in the RS232 9pin connector of the converter to the COM1 or COM2 Port of the PC Install and run the FINGER006 Application Software Figure RS422 Communi...

Страница 21: ...S232 9pin connector of the converter to the COM1 or COM2 port of the PC Install and run FINGER006 Application Software Figure RS422 Communication between FINGER006s and the Host PC 9 3 TCP IP Converte...

Страница 22: ...the Setup Menu For a setup or FINGER006 setting adjustment you have to enter the SETUP MENU first To do so press the 0 key 8 times for Master ID Default 00000000 and the user can get into the SETUP ME...

Страница 23: ...events and User can t change Maximum Number of Cardholder IDs because FINGER006 doesn t have the controller inside 10 5 Registering Cardholder IDs To add new cardholder IDs to the FINGER006 enter the...

Страница 24: ...EEN LED on Exit Button To make a request for exiting from inside an Exit Button Or External Reader can be used The Door Relay1 will open for 3 seconds Defaults with the on Alarms Unregistered Password...

Страница 25: ...to other SETUP MENUs by pressing F1 key for SETUP MENU F1 F2 key for SETUP MENU F2 F3 key for SETUP MENU F3 and F4 key for SETUP MENU F4 There are several SUB MENUs for each main SETUP MENU and you ca...

Страница 26: ...26 12 1 SETUP MENU F1...

Страница 27: ...lication software It is also important to make sure each device on a loop has a unique address To change the communication address of the FINGER006 press ENT enter the desired 3 Digit address in the 0...

Страница 28: ...s can access the door by presenting their card or entering their ID number and then verifying their identity by both a fingerprint and a password You can decide which combination of RF card fingerprin...

Страница 29: ...wish to use master fingerprint in which case you will be asked to place your fingerprint on the scanner twice in the next step When the Master ID card registration is successfully completed the LCD d...

Страница 30: ...ENT and then press 1 to confirm If you wish to cancel and exit press 0 instead 8 CARD ID CLEAR 8 CARD ID CLEAR 1 YES 0 NO Event clear allows you to delete all the event data from the FINGER006 CAUTIO...

Страница 31: ...31 12 2 SETUP MENU F2...

Страница 32: ...when Buzzer Output is defined in In Output Define 4 LED_BUZZER_CON GL03 YL03 BZ01 This function controls the LED and Buzzer of the reader GL Green LED controls the card reading status YL Yellow LED co...

Страница 33: ...d by default Caution If you choose Disable you cannot gain access via password input when using RF PW mode You can change the Output Mode when you press function keys 4BIT Burst 4bit burst will be out...

Страница 34: ...mart cards To do so you must change the Data BYTE setting to 2BYTE To change the setting press ENT and press 4 or 6 to select 4BYTE or 2BYTE and press ENT to confirm Range of Card Number FINGER006SR O...

Страница 35: ...he FINGER006 or enter the card number ID via the keypad and press ENT NOTE A Card Number ID can be 4 to 8Digits long For the FINGER006SR it can be 4 to 10Digits long For more information about the Car...

Страница 36: ...layed on the LCD Description of Fields z PW Password Enter the 4Digit password Password verification can be enabled in 12 1 4 Reader1 Mode This field is compulsory even if you do not use password veri...

Страница 37: ...rd on the list Press 4 or 6 to view the information of the previous or next card The FIRST ID or LAST ID message will appear if you are viewing the first or last ID If there is no card data the LCD wi...

Страница 38: ...38 12 4 SETUP MENU F4...

Страница 39: ...39...

Страница 40: ...to test the memory of the FINGER006 To begin the test press ENT If the test is successful the LCD will display the TEST PASSED message Press any key to finish the test If the test is unsuccessful the...

Страница 41: ...y to exit OUTPUT 1 OFF PRESS ANY KEY 4 LCD TEST LCD Test allows you to test the LCD of the FINGER006 To begin the test press ENT Once the test begins the LCD will display a series of different screens...

Страница 42: ...ck the status of Input Ports and DIP switches Communication Address Setting Switches To begin the test press ESC 1 DIP Switch 1 ON 2 OFF It shows how the DIP switch on the back of the FINGER006 is set...

Страница 43: ...d try again after powering the FINGER006 off and back on TEST PASSED PRESS ANY KEY 9 IDENTIFICATION Identification Mode is a feature that allows users to use just fingerprint verification without havi...

Страница 44: ...or wet the FINGER006 will adjust the fingerprint images according to the environment to improve the authentication rate To change the setting press ENT and press 4 or 6 to select NORMAL DRY or WET an...

Страница 45: ...ingerprints are registered in your FINGER006 and how many can be registered in total Depending on the specification of the fingerprint module in use the total fingerprint capacity can be 1000 2000 or...

Страница 46: ...BURST 7 Output Type NOMAL MODE 8 LCD Display STATUS 19 DEVICE INFO FIM2030 HD Device Info shows you the model name of the fingerprint module on your FINGER006 18 FP TEST FP Test allows you to test the...

Страница 47: ...ant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may...

Страница 48: ...AR PURPOSE IDTECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from...

Страница 49: ...49 16 Template...

Страница 50: ...t along with the RAM Code and send it to IDTECK RMA Center Product without RMA Code is not accepted If you have any questions or problems regarding the RMA services please contact us using the followi...

Страница 51: ...HE60 The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82...

Отзывы: