53
* Default Output Setting for Input Circumstance
9.7.1 OUTPUT SETTING FOR READER#1 ID OK LEVEL 1
Output Time setting from 9.7.2 to 9.7.14 is the same as 9.7.1 RD1 ID OK LV1 Output setting.
OUTPUT
Door
Relay
(DR)
Alarm
Relay
(AR)
TTL#1
(T1)
TTL#2
(T2)
Buzzer
(BZ)
[1] Reader#1 ID OK LV1
03
00
00
00
00
[2] Reader#1 ID OK LV2
05
00
00
00
00
[3] Reader#1 ID OK LV3
05
00
00
00
00
[4] Reader#1 ID OK LV4
05
00
00
00
00
[5] Reader#1 ID Error
00
03
00
00
00
[6] Reader#1 T/S Error
00
03
00
00
00
[7] Reader#1 APB Error
00
03
00
00
00
[8] Reader#2 ID OK LV1
03
00
00
00
00
[9] Reader#2 ID OK LV2
05
00
00
00
00
[10] Reader#2 ID OK LV3
05
00
00
00
00
[11] Reader#2 ID OK LV4
05
00
00
00
00
[12] Reader#2 ID Error
00
03
00
00
00
[13] Reader#2 T/S Error
00
03
00
00
00
[14] Reader#2 APB Error
00
03
00
00
00
. You can program
☞
OUTPUT activating time when the user ID is granted the access from the Reader#1. The
value put here is value x second when the Time Unit set to 1 second and value/10 second when the Time Unit
set to 0.1 sec. This Output Time is applied for the users registered with Level#1 output.
You can set the time from 00 to 98 seconds (0.0 to 9.8 seconds if Time Unit set to 0.1 sec.) and if you put the
value “99”, the Output will activate forever until you reset the Output.
Press <4> or <6> key to select Input Sources then press <ENT> key to program the Output time.
DR: Door Relay Output Time
AR: Alarm Relay Output Time
T1: TTL#1 Output Time
T2: TTL#2 Output Time
BZ: Buzzer Output Time
Содержание GE313
Страница 1: ...UOPERATING MANUAL ACCESS CONTROLLER MODEL GE313 ...
Страница 32: ...32 9 2 F2 SETUP MENU ...
Страница 36: ...36 U9 3 F3 SETUP MENU ...
Страница 41: ...41 9 4 F4 SETUP MENUU 9 4 1 ID REGISTRATION 1 Registration by RF Card ...
Страница 46: ...46 9 5 F5 SETUP MENU 9 5 1 TIME SCHEDULE ...
Страница 49: ...49 9 6 F6 SETUP MENU ...
Страница 52: ...52 9 7 F7 SETUP MENU ...
Страница 68: ...68 A S REQUEST FORM ORIGINAL ...
Страница 69: ...69 A S REQUEST FORM SAMPLE ...
Страница 70: ...70 MEMO ...