38
9.3.3 TIME UNIT SETTING
9.3.4 OUTPUT T/S+ID
.
☞
This menu is to define time unit for 5 output ports.
1sec: Output Time will be calculated by one second time unit for in/out definition.
0.1sec: Output Time will be calculated by 1/10 second time unit (100ms) for in/out definition
Ex) If you want to activate Door Relay (Relay #1, DR) for 3 second, you have to set as follow.
- Set Output Time Unit to 1 SEC.
- Set Door Relay (DR) Output Time to “03”
Ex) ) If you want to activate Door Relay (Relay #1, DR) for 0.5 second, you have to set as follow.
- Set Output Time Unit to 0.1 SEC.
- Set Door Relay (DR) Output Time to “05”
☞
.
Output Time SID is to unlock the door when the first user grants the access during the Time Interval
of the Time Schedule. The door will be locked just after the Time Interval period is over.
UNUSE: Door will unlock at the beginning of the Time Interval of the Time Schedule code.
USE: Door will unlock when the first user grants the access during the Time Interval of the Time Schedule.