APPENDIX
A. THE RELATION BETWEEN INPUT AND OUTPUT (DEFAULT)
* Default Output Setting for Input Sources
* Index No. [1] ~ [6]:
The value indicates operation time (second) of each output for the input signal.
* Index No. [7]:
The value indicates time schedule code (index) that each output operation has to
be applied.
* Index No. [8]:
The value indicates the time schedule code (index) that each input #1(Exit
button) ~#5 operation has to be applied.
* Index No. [9]:
The value indicates the type of each input #1(Exit button) ~#5 operation.
The “00” is NO(Normal Open) type.
The “01” is NC(Normal Close) type.
OUTPUT
INPUT
Door
Relay
(DR)
Alarm
Relay
(AR)
TTL#1
(T1)
TTL#2
(T2)
Buzzer
(BZ)
[1] EXIT BUTTON
03
00
00
00
00
[2] DOOR CONTACT
00
99
00
00
00
[3] AUX Input #1
00
00
00
00
00
[4] AUX Input #2
00
00
00
00
00
[5] TAMPER ALARM
00
99
99
99
99
[6] DURESS ALARM
00
00
00
00
00
[7] OUTPUT TIME SCHEDULE
00
00
00
00
00
[8] INPUT TIME SCHEDULE
00
00
00
00
00
[8] INPUT TYPE
00
00
00
00
00
Содержание GE313
Страница 1: ...UOPERATING MANUAL ACCESS CONTROLLER MODEL GE313 ...
Страница 32: ...32 9 2 F2 SETUP MENU ...
Страница 36: ...36 U9 3 F3 SETUP MENU ...
Страница 41: ...41 9 4 F4 SETUP MENUU 9 4 1 ID REGISTRATION 1 Registration by RF Card ...
Страница 46: ...46 9 5 F5 SETUP MENU 9 5 1 TIME SCHEDULE ...
Страница 49: ...49 9 6 F6 SETUP MENU ...
Страница 52: ...52 9 7 F7 SETUP MENU ...
Страница 68: ...68 A S REQUEST FORM ORIGINAL ...
Страница 69: ...69 A S REQUEST FORM SAMPLE ...
Страница 70: ...70 MEMO ...