50
* Default Output Setting for Input Sources
9.6.1 EXIT BUTTON OUTPUT SETTING
9.6.2 DOOR CONTACT OUTPUT SETTING
9.6.3 AUX INPUT#1 OUTPUT SETTING
9.6.4 AUX INPUT#2 OUTPUT SETTING
9.6.5 TAMPER ALARM OUTPUT SETTING
9.6.6 DURESS ALARM OUTPUT SETTING
Output Time setting for above Input Sources are the same as 9.6.1 Exit Button Output setting.
OUTPUT
Door
Relay
(DR)
Alarm
Relay
(AR)
TTL#1
(T1)
TTL#2
(T2)
Buzzer
(BZ)
[1] EXIT BUTTON
03
00
00
00
00
[2] DOOR CONTACT
00
99
00
00
00
[3] AUX Input #1
00
00
00
00
00
[4] AUX Input #2
00
00
00
00
00
[5] TAMPER ALARM
00
99
99
99
99
[6] DURESS ALARM
00
00
00
00
00
[7] OUTPUT TIME SCHEDULE
00
00
00
00
00
[8] INPUT TIME SCHEDULE
00
00
00
00
00
[9] INPUT TYPE
00
00
00
00
00
. You can program
☞
OUTPUT activating time when the EXIT button pressed. The value put here is value x
second when the Time Unit set to 1 second and value/10 second when the Time Unit set to 0.1 sec.
You can set the time from 00 to 98 seconds (0.0 to 9.8 seconds if Time Unit set to 0.1 sec.) and if you put the
value “99”, the Output will activate forever until you reset the Output.
Press <4> or <6> key to select Input Sources then press <ENT> key to program the Output time.
DR: Door Relay Output
AR: Alarm Relay Output
T1: TTL#1 Output
T2: TTL#2 Output
BZ: Buzzer Output
Содержание GE313
Страница 1: ...UOPERATING MANUAL ACCESS CONTROLLER MODEL GE313 ...
Страница 32: ...32 9 2 F2 SETUP MENU ...
Страница 36: ...36 U9 3 F3 SETUP MENU ...
Страница 41: ...41 9 4 F4 SETUP MENUU 9 4 1 ID REGISTRATION 1 Registration by RF Card ...
Страница 46: ...46 9 5 F5 SETUP MENU 9 5 1 TIME SCHEDULE ...
Страница 49: ...49 9 6 F6 SETUP MENU ...
Страница 52: ...52 9 7 F7 SETUP MENU ...
Страница 68: ...68 A S REQUEST FORM ORIGINAL ...
Страница 69: ...69 A S REQUEST FORM SAMPLE ...
Страница 70: ...70 MEMO ...