LX505/LX505SR QUICK INSTALLATION GUIDE
11
5.4 External Reader Connection
(Figure: External Reader Connection)
Proximity Reader Connection
- Connect (+) wire of the Proximity Reader to DC +12V of power supply.
- Connect (-) wire of the Proximity Reader to GND(-) of power supply.
- Connect Data-0 wire of the Proximity Reader to the Pink wire of LX505/LX505SR.
- Connect Data-1 wire of the Proximity Reader to the Sky Blue wire of LX505/LX505SR.
Compatible Readers (External Reader)
LX505:
- Standard 26bit Wiegand format proximity readers
- Standard 26bit W 8bit burst format proximity and keypad reader
LX505SR:
- Standard 34bit Wiegand format proximity reader
- Standard 34bit W 8bit burst format proximity and keypad reader
Wiegand Data 0(Pink)
Wiegand Data 1(Sky blue)
DC12V (+) GND (-)
+ (Red)
Power Supply
- (Black)
Proximity Reader