 LX505/LX505SR QUICK INSTALLATION GUIDE 

 

13 

 

 

5.5.2 RS485 Communication Connection for Standalone Unit 

An  RS485/RS232 converter is needed to for  RS485 communication  between the  LX505/LX505SR  and a  host  PC. 
Please follow the steps below. 

 
 

 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

(Figure: RS485 Communication Connection for standalone unit)

 

 

- Connect RS485-RTX (+) (Yellow wire) of LX505/LX505SR to RS485-A port of the converter. 
- Connect RS485-RTX (-) (Gray wire) of LX505/LX505SR to RS485-B port of the converter. 
- Plug the 9-pin connector of the converter into the COM1 or COM2 port of the host PC. 
- Install then run the LX505/LX505SR application software (STARWATCH TIME PRO, LX ACCESS PRO II, 

STARWATCH STANDARD). 

 

 
 
 

 

When you connect RS232/RS485 converter with LX505/LX505SR, connect Termination Resistor to both of 
beginning and end points of the wire as the figure above. If the length of communication wire is too long 
in  one  communication  loop,  it causes  communication  problem  from  the  cracked  data  or  decrement.  To 

prevent it, connect Termination Resistor as the figure above. But, don‟t use Termination Resistor for short-
distance  communication  wire.  If  you  use  Termination  Resistor  in  short-distance,  it  could  cause 
communication errors. 

 

 
 
 
 

 
 
 
 

RS485 

RS232 

Host PC 

RS485/RS232 
Convertor 

Max. 1200m 

Gray 

Yellow 

Termination 

Resister 

Termination 
Resistor 

Caution   

Содержание LX505

Страница 1: ...Quick Installation Guide Proximity PIN Access Controller ...

Страница 2: ...issing please contact a nearby distributor or IDTECK LX505 LX505R Wall Mount Manual CD Quick installation Guide 2PIN connector 1ea 3PIN connector 1ea 4PIN connector 1ea 5PIN connector 1ea 6PIN connector 1ea 8PIN connector 1ea Diode 2ea 2 2K resister 4ea 3 5 X 40mm screws 4ea 3 5 X 12mm screws 4ea 3 X 8mm screws 1ea 6 X 30mm screws 4ea ...

Страница 3: ...n LED turns on when relay 1 becomes active The yellow LED turns on when relay 2 becomes active 3 Menu Button There are 12 menu buttons F1 to F12 Press a menu button to enter the corresponding menu F10 to F12 menu buttons are unavailable for LX505 LX505SR 4 Input Button It is the numerical button to input number or to define direction Left right direction buttons Up down direction buttons Select bu...

Страница 4: ...akes sound 3 2PIN Connector Connect the power cable 4 3PIN Connector Connect the RS232 communication cable to connect serial print 5 6PIN Connector Connect the input and output cable 6 8PIN Connector Connect the relay cable 7 Initialization Switch This is used to initialize LX505 LX505SR 8 LED These LED indicate Communication status 9 4PIN Connector This is the Preliminary connector for extension ...

Страница 5: ...d Data 0 Wiegand Data 0 Pink Wiegand Data 1 Wiegand Data 1 Cyan CON 4 5PIN CONNECTOR RS485 RTX RS485 RTX Yellow wire RS485 RTX RS485 RTX Gray wire RS232 TX RS232 TX Black wire with white stripe RS232 RX RS232 RX Red wire with white stripe RS232 GND RS232 GND Black CON 5 8PIN CONNECTOR Door Relay NC NC 1 Blue wire with white stripe Door Relay COM COM 1 Gray wire with red stripe Door Relay NO NO 1 W...

Страница 6: ... INSTALLATION GUIDE 6 3 SYSTEM CONFIGURATION Figure System Configuration RS232 RS485 Converter Host PC DC12V Power Supply DC12V Power Supply RS232 RS485 RS485 Exit Button RF Reader RF Reader Door Lock Exit Button Door Lock ...

Страница 7: ...6 32 holes for at least 4 mounting points 2 Drill a 1 2 hole on the center of the Wall Mount 3 Using 4 screws install the Wall Mount to the proper location 4 Take out the cable through the center hole 5 After the wiring is done put the LX505 LX505SR on the Wall Mount and screw it Figure Wall Mount Do not install LX505 LX505SR on a metal wall Otherwise the radio frequency from the metal frame will ...

Страница 8: ...X505 LX505SR Connect the other wire of Exit Button to GND of LX505 LX505SR Door Contact Sensor Connection Connect one wire of Door Contact Sensor to Yellow with Red stripe wire of LX505 LX505SR Connect the other wire of Door Contact Sensor to GND of LX505 LX505SR Auxiliary Input Device Connection Applicable to Aux Input 1 Green wire Aux Input 2 Green with white stripe wire Connect one wire of Auxi...

Страница 9: ...nnection for Power Fail Safe Door Lock Connect COM wire of Door Relay Gray with Red stripe to 12V Connect NC wire of Door Relay Blue with White stripe to wire of Door Lock Connect GND wire to wire of Door Lock Door Relay Connection for Power Fail Secure Door Lock Connect COM wire of Door Relay Gray wire with Red stripe to 12V Caution Door Relay Alarm Relay COM gray with red stripe NO white with re...

Страница 10: ...ommunication unintended changes in system setting etc Also if you connect the diode to contrary polarity the diode will be burnt due to high current so must connect it in the correct direction 1N4004 1N4007 or equivalent diode are included in the gift box 24V Door Lock and Automatic Door Connection When you control 24V door lock or automatic door wire the door lock depending on Power Fail Safe or ...

Страница 11: ...Reader to the Pink wire of LX505 LX505SR Connect Data 1 wire of the Proximity Reader to the Sky Blue wire of LX505 LX505SR Compatible Readers External Reader LX505 Standard 26bit Wiegand format proximity readers Standard 26bit Wiegand 8bit burst format proximity and keypad reader LX505SR Standard 34bit Wiegand format proximity reader Standard 34bit Wiegand 8bit burst format proximity and keypad re...

Страница 12: ...tion Connect RS232 TX Black with White stripe wire of LX505 LX505SR to the pin 2 RXD of 9 pin connector Connect RS232 RX Red with White stripe wire of LX505 LX505SR to the pin 3 TX of 9 pin connector Connect GND Black wire to the pin 5 of the 9 pin connector Plug in the 9 pin female connector to COM1 or COM2 Port of the Host PC Install and run the LX505 LX505SR application software STARWATCH TIME ...

Страница 13: ...all then run the LX505 LX505SR application software STARWATCH TIME PRO LX ACCESS PRO II STARWATCH STANDARD When you connect RS232 RS485 converter with LX505 LX505SR connect Termination Resistor to both of beginning and end points of the wire as the figure above If the length of communication wire is too long in one communication loop it causes communication problem from the cracked data or decreme...

Страница 14: ...05SR to RS485 A port of the converter Connect RS485 RTX Gray wire of the LX505 LX505SR to RS485 B port of the converter Plug the 9 pin connector of the converter into the COM port of the host PC Install and run the LX505 LX505ST application software STARWATCH TIME PRO LX ACCESS PRO II STARWATCH STANDARD When you connect RS232 RS485 Converter with LX505 LX505SR connect Termination Register to both ...

Страница 15: ...ule IIM7100A Setting For TCP IP communication set information for Network and Serial communication through TCP IP Module IIM7100 setting program IIM100A Configuration Tool 1 Install TCP IP Module IIM7100 setting program IIM100A Configuration Tool The Program to set network and check operation status is contained in Application software TARWATCH TIME PRO LX ACCESS PRO II STARWATCH STANDARD CD Insta...

Страница 16: ...LX505 LX505SR controller click Search button 3 All TCP IP Modules connected on network are displayed In the Board List MAC address of TCP IP Module is displayed 4 Check MAC address of TCP IP Module described on TCP IP module and then select it Setting information is displayed as below ...

Страница 17: ... network Not duplicated Subnet Mask The Subnet Mask assigned from corresponding network Not duplicated Port above 5000 Server IP 0 0 0 0 Port below 0 Mode Server Mode 6 Select Serial tab Select serial communication setting value Speed Data Bit Parity Stop Bit Flow of selected TCP IP module Select 57600 for Speed 8 for Data Bit None for Parity 1 for Stop Bit CTS RTS for Flow Refer to table below Co...

Страница 18: ...Setting Value Inactivity Time 30000 Time 0 Size 0 Char 00 8 If all setting process is completed click Setting to apply network information to TCP IP module After setting is completed Complete Setting message is displayed Click OK and finish setting process ...

Страница 19: ...Figure RS232 Communication between LX505 LX505SR and a Serial Printer Connect RS232 TX sky blue with white stripe wire to the pin 2 RXD of the 9 pin connector Connect RS232 RX pink with white stripe wire to the pin 3 TX of the 9 pin connector Connect GND Black wire to the pin 5 of the 9 pin connector Plug in the 9 pin female connector to COM1 or COM2 Port of the serial printer Set the Print Output...

Страница 20: ...ntil the Initialize OK message appears on the screen It takes about 8 seconds then release the Initialization switch 4 Once pressing 1 button initialization process starts and appears Wait message on the screen To cancel initializing the system press 0 5 When the Initializing is done you will move to the standby screen Caution initialization process will restore all previous setting values to the ...

Страница 21: ... enter F5 SETUP MENU press F5 key 3 There are several SUBMENUS inside each SETUP MENU and you can move to other SUBMENUs by pressing 4 and 6 key If you don t press any key within 60 seconds or press ESC key the system will exit from the SETUP MENU and returns to the normal operating mode You can change the Master ID in the F7 SETUP MENU 6 3 Language setting 1 Select LANGUAGE in F1 SETUP MENU and t...

Страница 22: ... second and day of the week in sequence YYYY year 4 digits MM month 2 digits DD day 2 digits hh hour 2 digits mm minute 2 digits ss second 2 digits w day of the week 1 digit 1 Sunday 2 Monday 3 Tuesday 4 Wednsday 5 Thusday 6 Friday 7 Saterday 4 After finishing Date Time setting press ENT key to save it Caution Enter each value for Date Time fitting with respective digits 2 SET DATE TIME 2 SET DATE...

Страница 23: ...be duplicated If it is duplicated some communication errors may occur 6 6 BAUD RATE SETTING LX505 LX505SR supports 9600 19200 38400 and 57600 bps and the default baud rate is 57600 bps 1 Press the F1 SETUP MENU button 2 Using 4 and 6 keys move to 8 BAUD RATE and then press ENT key 3 Using 4 and 6 keys move to other baud rate and then select baud rate by pressing ENT key Select the baud rate among ...

Страница 24: ... register ID through a card If you select card you can register the ID through card For PIN registration select PIN and use the keypad to register the ID 4 Present the card onto the LX505 LX505SR 5 Card ID is displayed on the LCD Then set each of PW TA TB C RD MA MB LV and then press ENT key Please refer to next page for details about PW TA TB C RD MA MV LV 1 REGISTRATION 1 REGISTRATION 1 CARD 2 P...

Страница 25: ... assignment for the card user No Description 0 READER 1 READER 2 assigned 1 READER 1 assigned 2 READER 2 assigned 3 READER 1 READER 2 assigned MA READER 1 operation mode for the registered user No Description 0 System Operation mode 1 ID mode 2 ID P W MB READER 2 operation mode for the registered user No Description 0 System Operation mode 1 ID mode 2 ID P W LV Output operation level for the regis...

Страница 26: ...tem and then press ENT key 3 Present the card to delete or enter the ID through keypad and then press ENT key 4 When the ID is deleted you will see a message of ID DELETED on the screen If the entered ID is not existing in the product you will see a message of UNREGISTERED ID on the screen If the entered ID is out of the acceptable range INVALID NUMBER message appears 2 ID DELETE 2 ID DELETE ENTER...

Отзывы: