LX505/LX505SR QUICK INSTALLATION GUIDE
17
5)
Select „Network‟ tab.
Input network information of selected TCP/IP module to „Local IP‟, „Subnet‟, „Gateway‟.
Network information can be assigned from network manager.
Input „5000‟ for „Port‟, „0.0.0.0‟ for „Server IP‟(default), „0‟ for „Server IP Port‟. Select „Server Mode‟ for
„Network Mode‟. Refer to table below.
Column Name
Setting Value
Local IP
The IP address assigned from corresponding network (Not duplicated)
Gateway
The Gateway assigned from corresponding network (Not duplicated)
Subnet Mask
The Subnet Mask assigned from corresponding network (Not duplicated)
Port (above)
5000
Server IP
0.0.0.0
Port (below)
0
Mode
Server Mode
6)
Select „Serial‟ tab.
Select serial communication setting value („Speed‟, „Data Bit‟, „Parity‟, „Stop Bit‟, „Flow‟) of selected TCP/IP
module.
Select „57600‟ for „Speed‟, „8‟ for „Data Bit‟, „None‟ for „Parity‟ „1‟ for „Stop Bit‟ „CTS/RTS‟ for „Flow‟. Refer to
table below.
Column Name
Setting Value
Speed
57600
DataBit
8
Parity
None
Stop Bit
1
Flow
CTS/RTS
7)
Select „Option‟ tab.
Select option values („Inactivity Time‟, „Time‟, „Size‟ and „Char‟ ) of selected TCP/IP module.
Select „30000‟ for „Inactivity Time‟, „0‟ for „Time‟, „0‟ for „Size‟, „00‟ for „Char‟. Refer to table below.
57600