
IDT SMBus Interfaces
PES32NT24xG2 User Manual
12 - 12
January 30, 2013
Notes
During the PES32NT24xG2 initialization, the SMBus/I2C-bus address allocated to each I/O expander
used in that system configuration should be written to the corresponding I/O Expander Address
(IOE[21:0]ADDR) field. The IOExADDR fields are contained in the I/O Expander Address (IOEX-
PADDR[5:0]) registers.
Hot-plug outputs and I/O expanders may be initialized via serial EEPROM. Since the I/O expanders and
serial EEPROM both utilize the master SMBus, no I/O expander transactions are initiated until serial
EEPROM initialization completes. Since no I/O expander transactions are initiated until serial EEPROM
initialization completes, it is not possible to toggle a hot-plug output through serial EEPROM initialization
(i.e., it is not possible to cause a 0
→
1
→
0 transition or a 1
→
0
→
1 transition).
Whenever the value of an IOEXPADDR field is written, SMBus write transactions are issued to the
corresponding I/O expander by the PES32NT24xG2 to configure the device. This configuration initializes
the direction of each I/O expander signal and sets outputs to their default value.
9
Lower
Port 13 hot-plug
Upper
Port 15 hot-plug
10
Lower
Port 17 hot-plug
Upper
Port 19 hot-plug
11
Lower
Port 21 hot-plug
Upper
Port 23 hot-plug
12
Lower / Upper
Hot-plug MRL inputs (Ports 0 through 7, 8, 10, 12, 14,
16, 18, 20, 22)
13
Lower / Upper
Hot-plug MRL inputs (Ports 9, 11, 13, 15, 17, 19, 21,
23)
14
Lower / Upper
Hot-plug electromechanical interlock (Ports 0, 2, 4, 6,
8, 12, 16, 20)
15
Lower / Upper
Hot-plug electromechanical interlock (Ports 1, 3, 5, 7,
10, 14, 18, 22)
16
Lower / Upper
Hot-plug electromechanical interlock (Ports 9, 11, 13,
15, 17, 19, 21, 23)
17
Lower / Upper
Link status (Ports 0 through 15)
18
Lower / Upper
Link activity (Ports 0 through 15)
19
Lower / Upper
Link status (Ports 16 through 23) / Link activity (Ports
16 through 23)
20
Lower / Upper
Port reset outputs (Ports 0, 2, 4, 6, 8, 12, 16, 20) /
Partition fundamental reset inputs (partitions 0 to 7)
21
Lower
Port reset outputs (Ports 1, 3, 5, 7, 9, 10, 11, 13, 14,
15, 17, 18, 19, 21, 22, 23)
SMBus I/O
Expander
Section
Functionality
Table 12.4 I/O Expander Functionality Allocation (Part 2 of 2)
Содержание PCI Express 89HPES32NT24xG2
Страница 20: ...IDT Table of Contents PES32NT24xG2 User Manual x January 30 2013 Notes...
Страница 24: ...IDT List of Tables PES32NT24xG2 User Manual xiv January 30 2013 Notes...
Страница 28: ...IDT List of Figures PES32NT24xG2 User Manual xviii January 30 2013 Notes...
Страница 56: ...IDT PES32NT24xG2 Device Overview PES32NT24xG2 User Manual 1 20 January 30 2013 Notes...
Страница 100: ...IDT Switch Core PES32NT24xG2 User Manual 4 22 January 30 2013 Notes...
Страница 124: ...IDT Switch Partition and Port Configuration PES32NT24xG2 User Manual 5 24 January 30 2013 Notes...
Страница 128: ...IDT Failover PES32NT24xG2 User Manual 6 4 January 30 2013 Notes...
Страница 148: ...IDT Link Operation PES32NT24xG2 User Manual 7 20 January 30 2013 Notes...
Страница 164: ...IDT SerDes PES32NT24xG2 User Manual 8 16 January 30 2013 Notes...
Страница 170: ...IDT Power Management PES32NT24xG2 User Manual 9 6 January 30 2013 Notes...
Страница 196: ...IDT Transparent Switch Operation PES32NT24xG2 User Manual 10 26 January 30 2013 Notes...
Страница 244: ...IDT SMBus Interfaces PES32NT24xG2 User Manual 12 40 January 30 2013 Notes...
Страница 247: ...IDT General Purpose I O PES32NT24xG2 User Manual 13 3 January 30 2013 Notes...
Страница 248: ...IDT General Purpose I O PES32NT24xG2 User Manual 13 4 January 30 2013 Notes...
Страница 330: ...IDT Switch Events PES32NT24xG2 User Manual 16 6 January 30 2013 Notes...
Страница 342: ...IDT Multicast PES32NT24xG2 User Manual 17 12 January 30 2013 Notes...
Страница 344: ...IDT Temperature Sensor PES32NT24xG2 User Manual 18 2 January 30 2013 Notes...
Страница 384: ...IDT Register Organization PES32NT24xG2 User Manual 19 40 January 30 2013...
Страница 492: ...IDT Proprietary Port Specific Registers PES32NT24xG2 User Manual 21 44 January 30 2013 Notes...
Страница 588: ...IDT NT Endpoint Registers PES32NT24xG2 User Manual 22 96 January 30 2013 Notes...
Страница 710: ...IDT JTAG Boundary Scan PES32NT24xG2 User Manual 25 12 January 30 2013 Notes...
Страница 743: ...IDT Usage Models PES32NT24xG2 User Manual 26 33 January 30 2013 Notes...
Страница 744: ...IDT Usage Models PES32NT24xG2 User Manual 26 34 January 30 2013 Notes...