MSD-72 Series User’s Guide
68
If automatic measurement execute only strating position changes it shows “NORMAL END”, and if the active
area is changed by “NORMAL MODE” or if you set aspect ratio from “NEXT ASPECT” or directly it shows
resolution which is set.
[IN6 AUTO SETUP]
1024x 768 60.00Hz
If there is no input signal on the input channel it shows “NOT AVAILABLE NOW” on the front VFD screen.
Press the “MENU/SET” key to perform automatic measurement.
Note:
In case the aspect ratio does not match or video is displayed on the position far from the correct position, set
the input timing in,
“9.6.2 The total number of horizontal dots”
,
, and
.
■
Operation from input channel selection key
You can execute the automatic measurement not only from this menu but also by pressing an input selection
key for 2 seconds or longer. By pressing an input selection key for 2 seconds, the auto measurement mode
with “NORMAL MODE” will be enabled. After that, pressing the same key for 3 seconds or longer, the auto
measurement mode with “NEXT ASPECT” will be enabled. (This auto measurement mode can be enabled
also by pressing the input key for 5 seconds or longer continuously.) Once you perform the function, from the
next time, it can be performed simply by pressing the key without pressing it for several seconds. This mode
can be canceled 5 seconds after the last auto measurement is executed.
Input channel selection key
・
IN8 or IN9 key (if IN8 and IN9 are analog)
【
See: 9.5.5 Selecting signal of DVI input connector
2 sec.
5 sec.
7 sec.
2 sec.
5 sec.
2 sec.
Terminates if no operation is
performed for 5 seconds
Automatic measurement starts if you press the
key within 5 seconds.
Automatic measurement starts
(NEXT ASPECT)
Automatic measurement starts
(NORMAL MODE)
Pressing and holding the
key
[Figure 9.15] Automatic measurement using input channel selection key