MSD-72 Series User’s Guide
138
9.16.10 Displaying EDID of sink device
Menu Top
→
OTHERS
→
EDID STATUS
Setting value [Table 9.51] EDID information of sink device
You can display EDID information of the sink device that is connected to the video output connector.
・
HDMI supported sink device: No.1 to No.6
・
Non-HDMI-supported sink device: No.1 and No.2
If no sink device is connected, the VFD screen shows “UNCONNECTED”. If the MSD cannot read EDID from
connected sink devices, the VFD screen shows “EDID READ ERROR”.
[Table 9.51] EDID information of sink device
No.
1
2
3
Screen
[OUT1]xxxx
1920x1080 148.50MHz
[OUT1]HDMI
RGB/422/444/420
[OUT1]
DVI
[OUT1]
24BIT COLOR
Upper row Monitor name
HDMI or nothing is displayed
-
Lower row Resolution, dot clock
Sampling structure
RGB
:
RGB
422
:
YCbCr 4:2:2
444
:
YCbCr 4:4:4
420
:
YCbCr 4:2:0
Or non-HDMI-supported sink
device
DVI: DVI device
Color depth
No.
4
5
6
Screen
[OUT1]
32/44.1/48/96kHz
[OUT1]16/20/24BIT
8CHANNEL COMPRESSED
[OUT1]
HDR:-- / SCDC:ON
Upper row
-
Audio bit length
-
Lower row Audio sampling frequency
Number of audio channels,
compressed audio
supported/not supported
(COMPRESSED)
HDR and SCDC
supported/not supported