MSD-72 Series User’s Guide
61
9.5 Input settings
9.5.1 No-signal input monitoring
Menu Top
→
INPUT SETTING
→
INPUT VIDEO DETECT
Setting for Each input channel (only digital input signal)
Setting value OFF, 2000ms to 15000ms (100 ms steps) [Default]: 10000ms
If you change the settings of EDID of the MSD or turn off/on the MSD, the source device may not output video
signal. Use this menu to set the monitoring time which is from when a source device stops outputting signal to
when the MSD requests the source device to output video signal.
Changing EDID
ON
OFF
Requesting source device to
output video signals
Monitoring time
Hot plug
ON
OFF
Video signals from
source device
Changing EDID
Monitoring
time
ON
OFF
Monitoring
time
Monitoring
time
Video output timing of source device
Video signals from
source device
Requesting source device to output video signals
[Figure 9.10] Monitoring absence of input [Figure 9.11] Repeating reset
Note:
If you use the monitor power-saving function or Dual monitor function of the PC, set this menu to “OFF”. The
PC that receives output request may cancel those functions.
If you set shorter time than the time which the source device outputs video, the source device may not output
video. In such case, set the longer time.