MSD-62 Series User’s Guide
122
[Table 9.27] Individual reply command of status acquisition commands
No.
Command
Description
Reply command to power status commands
1
%
1
P
O
W
R
=
0
(CR)
Stand by
2
%
1
P
O
W
R
=
1
(CR)
Power ON
3
%
1
P
O
W
R
=
2
(CR)
Cooling
4
%
1
P
O
W
R
=
3
(CR)
Warming up
Reply command to input status commands
1
%
1
I
N
P
T
=
1
*1
(CR)
RGB selected
2
%
1
I
N
P
T
=
2
*1
(CR)
VIDEO selected
3
%
1
I
N
P
T
=
3
*1
(CR)
DIGITAL selected
4
%
1
I
N
P
T
=
4
*1
(CR)
STORAGE selected
5
%
1
I
N
P
T
=
5
*1
(CR)
NETWORK selected
Get mute settings
1
%
1
A
V
M
T
=
3
0
(CR)
Video+audio Mute OFF
2
%
1
A
V
M
T
=
1
1
(CR)
Video Mute ON
3
%
1
A
V
M
T
=
2
1
(CR)
Audio Mute ON
4
%
1
A
V
M
T
=
3
1
(CR)
Video+audio mute ON
Get error status
1
%
1
E
R
S
T
=
*2
*3
*4
*5
*6
*7
(CR)
Get time and status of lamp
1
%
1
L
A
M
P
=
*8 (SP)
*9
(CR)
Get list of input switching
1
%
1
I
N
S
T
=
*10 (CR)
Get projector name
1
%
1
N
A
M
E
=
*11 (CR)
Get manufacturer name
1
%
1
I
N
F
1
=
*12 (CR)
Get product name
1
%
1
I
N
F
2
=
*12 (CR)
Get other information (optional)
1
%
1
I
N
F
O
=
*12 (CR)
*1 Input number, which is any of “1” to “9”, but types and the numbers of selectable input connectors differ
depending on connected projectors.
*2 Fan error.
*3 Lamp error
*4 Temperature error
*5 Cover open error
*5 Filter error
*7 Other errors
For *2 to *7: 0: Error not detected or no detect error function, 1: Warning, 2: Error
*7 Accumulated time of lamp, which is any of 0 to 99999.
(For projectors that do not count the accumulated time, the value is 0 at all times.)
*8 Whether the lamp illuminates or not (0 or 1).
0: Not illuminate, 1: Illuminates
For devices containing multiple lamps, accumulated time and lightning state for each device are replied
in sequence. For example, if a device containing three lamps, the following command is replied:
“%1LAMP=accumulated time 1(SP) lightning state 1(SP) accumulated time 2(SP) lightning state 2(SP)
accumulated time 3(SP) lightning state 3
CR”
*9 Source number, which is input switchable. Any of 11 to 59 (Meaning is the same as that of “%INPT”
command). For devices containing multiple inputs, multiple statuses separated with a (SP) are sent. For
example, for a device having two inputs, “%1INST= source number1 (SP) source number2
CR
” is sent.
*10 20 to FF in hex: up to 64 characters.
20 to 7F in hex: up to 32 characters.