MSD-62 Series User’s Guide
111
9.12 RS-232C
The RS-232C connector of the MSD can output communication command control from PCs and control
command to external devices from the MSD. The operation mode will be switched according to “
”.
【
See: 9.14 Setting control command
9.12.1 RS-232C communication setting
Menu Top
→
COM PORT
→
PARAMETERS
Setting for RS-232C channel
Setting value [Table 9.19] RS-232C setting items
[Table 9.20] RS-232C setting items
Setting item
Setting value
Default
Baud rate [bps]
4800, 9600, 19200, 38400
9600
Data bit length [bit]
8, 7
8
Parity check
NONE, EVEN, ODD
NONE
Stop bit [bit]
1, 2
1
You can set the RS-232C communication.
Press the MENU/SET key to apply the setting.
9.12.2 RS-232C operation mode
Menu Top
→
COM PORT
→
FUNCTION
Setting for RS-232C channel
Setting value RECEIVER [Default], TRANSMITTER
You can set the operation mode to “RECEIVER” mode in which the MSD is controlled externally or
“TRANSMITTER” mode in which the MSD controls peripheral devices.
Press the MENU/SET key to apply the setting.