MSD-62 Series User’s Guide
115
9.13.3 TCP port number
Menu Top
→
LAN
→
PORT NUMBER
Setting for Each connection
Setting value [Table 9.22] TCP port number
[Table 9.22] TCP port number
For
Setting value
Communication command control
23, 1100, 6000 to 6999
WEB browser control
80, 5000 to 5999
[Default] Connections 1 to 3 = 1100; Connections 4 to 6 = 23;
Connections 7, 8 = 80
You can set the TCP port number to control the MSD externally.
This setting will valid if “RECEIVER” is selected for “
”.
Each connection will be divided into connections for communication command control and WEB browser
depending on the set port numbers.
Press the MENU/SET key to apply the setting.
9.13.4 MAC address
Menu Top
→
LAN
→
MAC ADDRESS
You can display the MAC address.
9.13.5 Setting HDBaseT LAN
Menu Top
→
LAN
→
HDBASET LAN
Setting for 2 HDBaseT output channels
MSD-6203: OUT1/OUT2, and OUT3
MSD-6204: OUT1/OUT2 and OUT3/OUT4
MSD-6206: OUT1/ OUT2, OUT3/OUT4, and OUT5/OUT6
MSD-6208: OUT1/OUT2, OUT3/OUT4, OUT5/OUT6, and OUT7/OUT8
Setting value
ON [Default], OFF
You can enable/ disable the LAN of HDBaseT output connector.
【
See: 9.13 LAN
Note:
Reboot the MSD to apply the setting.