HS5E Miniature Interlock Switches with Solenoid
Standard - Solenoid Lock
Interlock Switch Status
Status 1
Status 2
Status 3
Status 4
Door Closed
•
Machine ready to
•
operate
Solenoid energized
•
Door Closed
•
Machine cannot be
•
operated
Solenoid de-energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid de-energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid energized
•
Door Status
Circuit Diagram (HS5E-A7Y)
Door
Closed (locked)
Closed (unlocked)
Open
Open
Contact Configuration
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23-24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23−24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open).
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
31−32
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
33−34
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
61−62
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
63−64
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Solenoid Power A1-A2 (all model)
ON (energized)
OFF (de-energized) OFF (de-energized)
ON (energized)
(Note 2)
The above contact confi guration shows the status when the actuator is inserted and locked.
•
Main Circuit: Connected to the control circuit of machine drive part, sending interlock signals of the protective door.
•
Monitor Circuit:
•
Sends monitoring signals of protective door open/closed status or protective door lock/unlock status.
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
A1
(–)
A2
(+)
53
41
24
12
54
42
23
11
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
HS5E-A7Y
HS5E-B7Y
HS5E-C7Y
HS5E-D7Y
HS5E-F7Y
HS5E-G7Y
HS5E-H7Y
HS5E-J7Y
A1
A2
24
11
23
12
42
41
(+)
54
53
(–)
51
52
41
42
12
23
11
24
22
11
21
12
41
53
41
12
11
11
12
42
41
41
42
12
11
11
12
42
41
41
42
12
11
21
22
51
21
22
32
31
21
22
33
34
61
62
51
52
51
52
63
64
54
42
52
42
Door Monitor
(Actuator inserted)
Lock Monitor
(Solenoid ON)
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Unlocked with Manual
Unlocking Key
Door Closed
•
Machine cannot be
•
operated
Solenoid de-energized
•
→
energized
Closed (unlocked)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF to ON
(Note 1) (Note 2)
Manual Unlock Status
UNLOCK
LOCK
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
26.4 (travel in mm)
5.3 6.9
3.3 (Locked position)
0
Monitor Circuit (unlocked, NO)
Monitor Circuit (door open, NO)
Monitor Circuit (locked, NC)
Monitor Circuit (door closed, NC)
Operation Chracteristics (reference)
(Actuator insertion position)
Contacts OFF (open)
Contacts ON (closed)
Main Circuit
The operation characteristics shown in the chart above are
•
of the HS9Z-A51. For other actuators, add 1.3 mm.
The operation characteristics show the contact status when
•
the actuator enters the entry slot of an interlock switch.
Note 1: Do not attempt manual unlocking when
the solenoid is energized.
Note 2: Do not energize the solenoid for a long
time while the door is open or when the
door is unlocked manually.