HS5E Miniature Interlock Switches with Solenoid
Circuit Diagrams and Operating Characteristics
Standard and Rear Unlocking - Spring Lock
Interlock Switch Status
Status 1
Status 2
Status 3
Status 4
Door Closed
•
Machine ready to
•
operate
Solenoid de-energized
•
Door Closed
•
Machine cannot be
•
operated
Solenoid energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid de-energized
•
Door Status
Circuit Diagram (HS5E-A4)
Door
Closed (locked)
Closed (unlocked)
Open
Open
Contact Configuration
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23-24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23−24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
31−32
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
33−34
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
61−62
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Main Circuit
11−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
63−64
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Solenoid Power A1-A2 (all model)
OFF (de-energized)
ON (energized)
ON (energized)
OFF (de-energized)
The above contact confi guration shows the status when the actuator is inserted and locked.
•
Main Circuit: Connected to the control circuit of machine drive part, sending interlock signals of the protective door.
•
Monitor Circuit: Sends monitoring signals of protective door open/closed status or protective door lock/unlock status.
•
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
A1
(–)
A2
(+)
53
41
24
12
54
42
23
11
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
Door Monitor
(Actuator Inserted)
Lock Monitor
(Solenoid OFF)
HS5E-A4
HS5E-B4
HS5E-C4
HS5E-D4
HS5E-F4
HS5E-G4
HS5E-H4
HS5E-J4
A1
A2
24
11
23
12
42
41
(+)
54
53
(–)
51
52
41
42
12
23
11
24
22
11
21
12
41
53
41
12
11
11
12
42
41
41
42
12
11
11
12
42
41
41
42
12
11
21
22
51
21
22
32
31
21
22
33
34
61
62
51
52
51
52
63
64
54
42
52
42
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Manual Unlock
Door Closed
•
Machine cannot be
•
operated
Solenoid de-energized
•
Closed (unlocked)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (de-energized)
UNLOCK
LOCK
LOCK
UNLOCK
Turn the manual
unlock key
(Note 1)
Press the rear
unlocking button
(Note 2)
Press
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
Note 1: Actuator can be unlocked manually for confi rming the
door movement before wiring and energizing, and also
for emergency situation such as power failure.
Note 2: When the operator is confi ned in a hazardous zone, the
actuator can be unlocked manually by pressing the rear
unlocking button.
The operation characteristics shown in the chart above are of the
•
HS9Z-A51. For other actuators, add 1.3 mm.
The operation characteristics show the contact status when the
•
actuator enters the entry slot of an interlock switch.
26.4 (travel in mm)
5.3 6.9
3.3 (Locked position)
0
Monitor Circuit (unlocked, NO)
Monitor Circuit (door open, NO)
Monitor Circuit (locked, NC)
Monitor Circuit (door closed, NC)
Operation Chracteristics (reference)
(Actuator insertion position)
Contacts OFF (open)
Contacts ON (closed)
Main Circuit
HS5E