715
HS5E Miniature Interlock Switches with Solenoid
Four-circuit Independent Output - Solenoid Lock
Interlock Switch Status
Status 1
Status 2
Status 3
Status 4
Door Closed
•
Machine ready to
•
operate
Solenoid energized
•
Door Closed
•
Machine cannot be
•
operated
Solenoid de-energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid de-energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid energized
•
Door Status
Circuit Diagram (HS5E-VA7Y)
Door
Closed (locked)
Closed (unlocked)
Open
Open
Contact Confi
guration
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23−24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23−24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Solenoid Power A1-A2 (all model)
ON (energized)
OFF (de-energized) OFF (de-energized)
ON (energized)
(Note 2)
The above contact confi guration shows the status when the actuator is inserted and locked.
•
Monitor Circuit: Sends monitoring signals of protective door open/closed status or protective
•
door lock/unlock status.
11
23
42
54
12
24
41
53
(+)
A2
(–)
A1
A1
(–)
A2
(+)
53
41
24
12
54
42
23
11
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
Monitor Circuit:
Door Monitor
(Actuator Inserted)
Lock Monitor
(Solenoid ON)
HS5E-VA7Y
HS5E-VB7Y
HS5E-VC7Y
HS5E-VD7Y
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
A1
A2
24
11
23
12
42
41
54
53
51
52
41
42
12
23
11
24
22
11
21
12
41
53
41
12
11
21
22
51
54
42
52
42
(+)
(–)
Unlocked with Manual
Unlocking Key
Door Closed
•
Machine cannot be
•
operated
Solenoid de-energized
•
→
energized
Closed (unlocked)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (de-energized) to
ON (energized)
(Note 1) (Note 2)
Manual Unlock Status
UNLOCK
LOCK
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
The operation characteristics shown in the chart above are of the HS9Z-A51.
•
For other actuators, add 1.3 mm.
The operation characteristics show the contact status when the actuator
•
enters the entry slot of an interlock switch.
Note 1: Do not attempt manual unlocking when the solenoid
is energized.
Note 2: Do not energize the solenoid for a long time while the
door is open or when the door is unlocked manually.
5.3
6.9
0 (Actuator insertion position)
26.4 (travel in mm)
3.3 (Locked position)
Monitor Circuit (unlocked, NO)
Monitor Circuit (door open, NO)
Monitor Circuit (locked, NC)
Monitor Circuit (door closed, NC)
Operation Chracteristics (reference)
Contacts OFF (open)
Contacts ON (closed)
HS5E