Monitored Maglock Instruction Manual 

 

CEB00XXX-53-000 

 

Issue 2          13 January 2020 

 
 

 
 

LASERMET  

MONITORED MAGLOCK 

 

INSTRUCTION MANUAL 

 
 
 

 

 

 
 
 
 

MONITORED MAGLOCK 

INSTALLATION 

 

Issue 2 

 
 
 
 
 
 

Summary of Contents for MONITORED MAGLOCK

Page 1: ...Monitored Maglock Instruction Manual CEB00XXX 53 000 Issue 2 13 January 2020 LASERMET MONITORED MAGLOCK INSTRUCTION MANUAL MONITORED MAGLOCK INSTALLATION Issue 2 ...

Page 2: ... Manual CEB00XXX 53 000 Page 2 of 8 Issue 2 13 January 2020 LASERMET Maglock Instruction Manual Contents 1 Safety Warnings 3 2 Concept 4 3 Installation 4 3 1 Mounting 5 4 Wiring 6 5 Specifications 7 6 Warranty 7 7 Contact Details 8 ...

Page 3: ...made to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into contact with each other or any other moving part when in use The parts should never be subject to impact or mechanical strain Safety switches should never be defeated or bypassed It is imperative ...

Page 4: ...ected to provide a complete laser interlock system Full support design and installation is available from Lasermet please contact us for any queries Contact details are given at the end of this manual 3 Installation Handle the equipment with care damaging the mating surfaces of the magnet or armature plate may reduce locking efficiency The magnet mounts rigidly to the door frame the armature plate...

Page 5: ... one 1 rubber washer sandwiched between two 2 steel washers STEP 3 Install the mounting plate Adjust the mounting plate so that it and the armature plate form a right angle Using the mounting plate as a template drill the wire hole Drill and install the remaining mounting screws STEP4 Fix the magnet to mounting plate with two m4 m6 screws supplied STEP 5 Install electrical wiring per instructions ...

Page 6: ...o V Check jumper for 12VDC operation 24VDC Input Required Power 0 25A minimum Connect the positive lead from a 24VDC power source to V Connect the ground lead from a 24VDC power source to V Check jumper for 24VDC operation Contacts Relay dry contacts are rated at 1A at 24VDC for safe operation Do not exceed this rating For a normally open switch connect the wires from the system to COM and NO For ...

Page 7: ...nty Lasermet provide a 12 month warranty for defects in materials and manufacture from the date of installation or delivery Installations completed by Lasermet are covered against defects in workmanship for 12 months Damage or defects caused by other factors are not covered For example industrial contamination incorrect cleaning storm damage Consequential loss is not covered under warranty Compens...

Page 8: ...to provide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries For sales and technical support Lasermet Ltd Lasermet House 137 Hankinson Road Bournemouth BH9 1HR United Kingdom Tel 44 0 1202 770740 Fax 44 0 1202 770730 Email sales lasermet com Website www la...