HR6S-BAC

 

Safety Module

Safety-Related Outputs

Number of relay contacts, Normally Open

4

Number of relay contacts, Normally Closed

1

Maximum short circuit current IK

1 kA

Maximum continuous current, Normally Open relay contacts

6 A

Maximum continuous current, Normally Closed relay contacts 3 A
Maximum total thermal current ∑I

THERM

16 A

Minimum current

10 mA

Utilization category as per UL 60947-5-1

B300 and R300 for Normally 
Open contacts
D300 and R300 for Normally 
Closed contacts

Utilization category as per IEC 60947-4-1 and IEC 60947-5-1

AC-1: 250 V
AC-15: 250 V
DC-1: 24 V
DC-13: 24 V

Maximum current, normally open relay contacts

AC-1: 5 A
AC-15: 3 A
DC-1: 5 A
DC-13: 3 A

Maximum current, normally closed relay contacts

AC-1: 3 A
AC-15: 1 A
DC-1: 3 A
DC-13: 1 A

External fusing

10 A, category gG, for Normally Open
4 A, category gG, for Normally Closed

Data Functional Safety

Defined safe state

Safety-related outputs are de-energized
Normally Open: open
Normally Closed: closed

Maximum Performance Level (PL), Category
(as per ISO 13849-1:2015)

Normally Open: PLe, Category 3
Normally Closed: PLc, Category 1

Maximum Safety Integrity Level (SIL)
(as per IEC 61508-1:2010)

Normally Open: 3
Normally Closed: 1

Safety Integrity Level Claim Limit (SILCL)
(as per IEC 62061:2005+AMD1:2012+
AMD2:2015)

Normally Open: 3
Normally Closed: 1

Type (as per IEC 61508-2)

B

Hardware Fault Tolerance (HFT)
(as per IEC 61508 and IEC 62061)

1

Stop Category for Emergency Stops
(as per ISO 13850 and IEC 60204-1)

0

Lifetime in years at an ambient temperature of 55 °C (131 °F) 20

Safe Failure Fraction (SFF)
(as per IEC 61508 and IEC 62061)

>99 %

Probability of Dangerous Failure per hour (PFH

D

) in 1/h

(as per IEC 61508 and ISO 13849-1)

0.95 × 10

-9

Mean Time To Dangerous Failure (MTTF

D

) in years

(as per ISO 13849-1)

2,300 (*1)

Average Diagnostic Coverage (DC

avg

)

(as per ISO 13849-1)

≥99 %

Maximum number of cycles
over lifetime

DC-13

24V DC 1 A: 1200000
24V DC 3 A: 275000

AC-1

250V AC 4 A: 90000

AC-15

250V AC 1 A: 90000
250 VAC 5 A: 70000

*1) According to ISO 13849-1 Annex K

For other specifications (common to all models), see page

 27

.

• Protects both the operator and the machine by immediately stopping 

dangerous movements when instructed to stop by the operator or when a 
failure in the safety circuit is detected.

• Reduced wiring for safety input part.
•  Slim module available with 4NO1NC safety output.

Terminal

Part No.

Supply Voltage

Push-in terminal

HR6S-BAC1C

24V AC/DC

Screw terminal

HR6S-BAC1P

24V AC/DC

• One sealing strip (see page

 28

) is included with each product.

HR6S-BAC 

Package Quantity: 1

22.5mm-wide module with 4NO1NC output

• See website for details on approvals and standards.

Sa

fety Approv

ed

  H

R6S

*

 - 1435.IM.13500

5/2

0

TÜV NORD Systems

GmbH & Co.KG

Monitoring of Emergency 
Stop circuits as per ISO 
13850 and IEC 60204-1, 
stop category 0

Monitoring of guards as 
per ISO 14119/14120 
with interlock switches

Overview of Application Functions

Содержание HR6S Series

Страница 1: ...Safety Relay Modules HR6S Improve productivity with predictive maintenance of safety systems Safety Relay Modules...

Страница 2: ...echnology IoT is being promoted at factories around the world for the purpose of optimizing productivity The optimal allocation of resources and predictive maintenance are important in such factories...

Страница 3: ...Tablet Safety relay module Safety relay module 3 Advanced Diagnostic and Output Functions SAFETY RELAY MODULE HR6S Not only diagnostic results but detailed information regarding safety relat ed parts...

Страница 4: ...ging the wiring Automatic and manual operation can be selected as well as startup test which requires monitoring cross circuit detection and pre start inspection For details see page 31 Set up to 7 ty...

Страница 5: ...HR6S AK A sealing strip to secure the protective cover is included preventing the dials from inadvertent adjustment or settings from being changed Protection Outputs can be expanded excluding HR6S AB...

Страница 6: ...al input can be used to cancel the off delay and immediately cut off the output Expanded 1 output can be set to either instantaneous or delay Indicates that safety related input is activated ERROR doe...

Страница 7: ...Delay 3NO 1NC 1NO Output expansion Status output Semiconductor All diagnostic results For details see page 31 Safety related output monitor Failure detection output Number of LEDs 6 5 6 6 8 8 16 3 2...

Страница 8: ...nitoring of RFID sensors Monitoring of guards as per ISO 14119 14120 with interlock switches Monitoring of guards as per ISO 14119 14120 with coded magnetic switches Monitoring of electro sensitive pr...

Страница 9: ...es Signal interlock monitoring No Synchronous monitoring No Dynamization No Signal interlock monitoring No Synchronous monitoring 0 5 s Dynamization No Signal interlock monitoring Yes Coded magnetic s...

Страница 10: ...13849 1 1 13 x 10 9 Mean Time To Dangerous Failure MTTFD in years as per ISO 13849 1 2 000 1 Average Diagnostic Coverage DCavg as per ISO 13849 1 99 Maximum number of cycles over lifetime DC 13 24V DC...

Страница 11: ...itoring 0 5 s Dynamization No Signal interlock monitoring Yes Synchronous monitoring 0 5 s Dynamization No Signal interlock monitoring Yes 1 PNP 2 2 OSSD DC CH S11 S12 A A DC CH S21 S22 PNP PNP DC CH...

Страница 12: ...o Dangerous Failure MTTFD in years as per ISO 13849 1 2 000 1 Average Diagnostic Coverage DCavg as per ISO 13849 1 99 Maximum number of cyclesover lifetime DC 13 24V DC 1 A 1 200 000 24V DC 3 A 180 00...

Страница 13: ...toring No Dynamization No Signal interlock monitoring Yes Synchronous monitoring 0 5 s Dynamization No Signal interlock monitoring Yes Synchronous monitoring No Dynamization No Signal interlock monito...

Страница 14: ...um continuous current Normally Closed relay contacts 3 A Maximum total thermal current ITHERM 12 A Minimum current 10 mA Utilization category as per UL 60947 5 1 B300 and R300 for Normally Open contac...

Страница 15: ...1200000 with Stop Category 0 24V DC 1 A 1200000 with Stop Category 1 24V DC 3 A 180000 with Stop Category 0 24V DC 3 A 275000 with Stop Category 1 AC 1 250V AC 4 A 180000 with Stop Category 0 250 VAC...

Страница 16: ...ization No Signal interlock monitoring Yes Synchronous monitoring No Dynamization No Signal interlock monitoring Yes Synchronous monitoring 0 5 s Dynamization No Signal interlock monitoring Yes 2 PNP...

Страница 17: ...ximum current 20 mA Terminal Part No Supply Voltage Push in terminal HR6S S1C 24V AC DC Screw terminal HR6S S1P 24V AC DC One sealing strip see page 28 is included with each product HR6S S Package Qua...

Страница 18: ...ency stop switches Interlock switch Two hand control switch IIIA DC CH CH S11 S12 S13 DC CH CH S21 S22 S23 S1 S2 S11 S12 S13 DC CH CH S21 S22 S23 DC CH CH DC CH CH S11 S12 S13 S1 S2 Dial 4 Dial 5 Sync...

Страница 19: ...namization No Signal interlock monitoring Yes Synchronous monitoring No Dynamization No Signal interlock monitoring Yes Synchronous monitoring 0 5 s Dynamization No Signal interlock monitoring Yes 2 P...

Страница 20: ...e 4 light curtains as per IEC 61496 1 Terminal Part No Supply Voltage Push in terminal HR6S DN1C 24V AC DC Screw terminal HR6S DN1P 24V AC DC One sealing strip see page 28 is included with each produc...

Страница 21: ...C CH S51 S52 CH S53 DC CH S61 S62 CH S63 1 Connection examples for coded magnetic switches such as HS7A IDEC are also included on the instruction sheet but certifications are not available Note Status...

Страница 22: ...S43 PNP PNP DC CH S51 S52 CH S53 PNP PNP DC CH S61 S62 CH S63 PNP PNP Dial 7 Dial 8 Synchronous monitoring No Dynamization No Signal interlock monitoring Yes Synchronization 0 5 s Dynamization No Sign...

Страница 23: ...or delayed relay contacts Additional Non Safety Related Outputs Output voltage 24V DC Maximum current 20 mA Data Functional Safety Defined safe state Safety related outputs are de energized Normally O...

Страница 24: ...F3 33 43 51 61 34 44 52 62 23 24 AC DC DC K1 K2 A1 A2 13 14 K5 K6 K4 S2 K3 K6 K5 S1 F2 F1 L1 33 34 23 24 AC DC DC DC Input Start Input CH DC CH DC CH K1 K2 A1 A2 S11 S12 Y1 Y2 S21 S1 S22 Z1 N 13 14 K3...

Страница 25: ...rdware Fault Tolerance HFT as per IEC 61508 and IEC 62061 1 Stop Category for Emergency Stops as per ISO 13850 and IEC 60204 1 0 Lifetime in years at an ambient temperature of 55 C 131 F 20 Safe Failu...

Страница 26: ...Start switch K3 to K6 Contactor M Motor PLC Programmable controller F1 to F4 Fuse Monitoring of Emergency Stop Switch Interlock Switch Input Device Connection Example Synchronous monitoring No Dynamiz...

Страница 27: ...mm2 24 to 12 AWG Two wires without wire ferrule 1 0 2 to 1 5 mm2 24 to 16 AWG Two wires with uninsulated wire ferrule 0 25 to 1 mm2 24 to 18 AWG Two wires with insulated wire ferrule 2 0 5 to 1 5 mm2...

Страница 28: ...e rails BAA1000 Recommended ferrules Item Wire cross section mm2 Stranded wire Part No Color Package Quantitiy AWG mm2 Ferrule with insulated cover Standard pack Push in terminal For single wire 20 0...

Страница 29: ...0 g HR6S DN 99 117 a 45 EXT Weight 350 g HR6S EP Weight 200 g HR6S BAC 99 117 a 45 EXT Weight 200 g 22 5 117 99 a MOD Designation Explanation a Push in terminal 10 mm Screw terminal 5 mm EXT Connector...

Страница 30: ...l error detected Module in defined safe state ERROR LEDs 4 Configuration error detected ERROR POWER Power supply error detected LED State Explanation ERROR Snn 2 Snn 2 Cross circuit detected at safety...

Страница 31: ...c start 1 No No 6 Manual automatic start 1 Yes No 7 Monitored start 2 No No 8 Monitored start 2 Yes No 5 Automatic start when start terminals Y1 and Y2 are short circuited 6 When the switch is used to...

Страница 32: ...rify that the sensor device providing the input signal is suitable for cross circuit detection by means of dynamization If it is not use an application function without dynamization or a sensor device...

Страница 33: ...of the safe operability of the safety relay module This product is not intended for use in applications that require a high degree of safety and reliability such as nuclear power railways aviation and...

Страница 34: ...short circuit fault detection when wiring from an input device HR1S AF HR5S C2S Total width 41 DOWN Cost 45 DOWN System with off delay control system HR1S ATE Total width 52 DOWN Cost 39 DOWN HR5S C2D...

Страница 35: ...instruments or the like that could endanger life or human health ii Use in applications that require a high degree of reliability such as provision systems for gas waterworks electricity etc systems t...

Страница 36: ...IDEC Corporation All Rights Reserved EP1796 0 USA IDEC Corporation EMEA APEM SAS China IDEC Shanghai Corporation IDEC Izumi H K Co Ltd Taiwan IDEC Taiwan Corporation Singapore IDEC Izumi Asia Pte Ltd...

Отзывы: