background image

 

 

 

 

 

 

 

 

 

 
 
 

 

 

 
 

 

 

 

 

Securel v3

 

 

 

 

 

 

 

IWAC 

 Securel v3 

 Encrypted Relay with KNX Secure 

 

 

 

 

 

 

 

 

 

ZIOSECV3 

 

U

S

E

R

 M

A

N

U

A

L

 

 

 

 

  

dsñkmfroi 

 

 

 

Application Program Version: 1.0 

 User manual edition: [1.0]_a 

 

 

 

www.zennio.com

   

 

 

 

 

 

 

Содержание Securel v3

Страница 1: ...Securel v3 IWAC Securel v3 Encrypted Relay with KNX Secure ZIOSECV3 USER MANUAL ds kmfroi Application Program Version 1 0 User manual edition 1 0 _a www zennio com...

Страница 2: ...2 CONTENTS Contents 2 1 Introduction 3 1 1 Securel v3 3 1 2 Access Control System 4 1 3 Installation 6 1 4 Start Up and Power Loss 9 2 Configuration 10 2 1 General 10 2 1 1 Door Opening object 11 2 1...

Страница 3: ...d information about the functionality and the configuration of the KNX Secure please refer to the specific manual Security KNX available in the Securel v3 product section at the Zennio website www zen...

Страница 4: ...nsmitted to Securel v3 by KNX bus Although not mandatory it is highly recommended to set KNX secure for this communication Securel v3 final element acting on the lock when granting access from access...

Страница 5: ...ent access management modules and the notification of certain events NFC card passive element for accessing to certain rooms As shown in the diagram Securel v3 can be used interchangeably with either...

Страница 6: ...ate the pairing mode Auxiliary power supply 3 slots for the connection of external 24VDC power supply Electric strike output 4 output ports for the insertion of the electric strike Encrypted communica...

Страница 7: ...tallation process See section 2 2 Test Prog Push button 8 a short press on this button sets the device into the programming mode Note if this button is held while plugging the device into the KNX bus...

Страница 8: ...st LED 9 Programming mode LED On red Safe mode LED Flashing red To get detailed information about the technical features of this device as well as on the installation and security procedures please re...

Страница 9: ...and the relay will not carry out any action on the lock until a first order is received from the access control module If Securel v3 was not paired remains in pairing mode Status after bus failure A...

Страница 10: ...the device 2 1 GENERAL The only parameterizable screen available is General All device functions can be configured from this screen ETS PARAMETERISATION Figure 2 General Relay Configuration Opening T...

Страница 11: ...ol module for example IWAC Out in the diagram in Figure 2 through this object will send opening commands to the Securel v3 that will trigger timed closures of the relay i e the opening of the door and...

Страница 12: ...pening Object Lock disabled enabled enables the 1 bit object Access Lock Opening Object which locks the action of the opening object Access Open Door Lock Object Polarity 0 Unlock 1 Lock 0 Lock 1 Unlo...

Страница 13: ...urel v3 is paired press the PAIR button for three seconds to remove the pairing Securel v3 is then in pairing mode Connect the Securel v3 to the device desired to pair with and they will be automatica...

Страница 14: ...d enables or permanently disabled serial port communication Serial Channel Lock enabled disabled enables the object Access Lock Serial Channel which locks the door opening action through the serial ch...

Страница 15: ...less disabled by parameter needs to be done by long pressing the Prog Test button for at least three seconds until the LED is no longer red and turns yellow From that moment once the button is release...

Страница 16: ...Test ON mode the actions received by each object are not taken into account the evaluation of their status is carried out when exiting this mode so that any change in the alarm status or blocking of...

Страница 17: ...rol in runtime When this checkbox is enabled object Lock Manual Control turns visible as well as two more parameters Value 0 Unlock 1 Lock 0 Lock 1 Unlock defines whether the manual control lock unloc...

Страница 18: ...nctional Range Name Function 1 1 Bit C T DPT_Trigger 0 1 Heartbeat Object to Send 1 Sending of 1 Periodically 2 1 Bit I C W DPT_Ack 0 1 Access Open Door 0 Open Door 1 Bit I C W DPT_Ack 0 1 Access Open...