41
REPLACEMENT OF PARTS
IMAX XTRA EL
-
Installation & Servicing
Fan Inlet
49 CONDENSATE TRAP REPLACEMENT
50 FLEXIBLE AIR DUCT REPLACEMENT
1. Refer to Frames 34 & 36.
2.
Slacken the hose clip on the flexible duct at the
fan inlet.
3.
Slacken the hose clip on the flexible duct at the
air inlet.
4.
Carefully remove the flexible duct and hose clips.
5.
To refit: Check the flexible duct for damage and
replace as necessary.
6.
Position the flexible duct over the air inlet and
secure with the hose clip.
7.
Postion the flexible duct over the fan inlet and
secure with the hose clip.
3
2
Air inlet
1. Refer to Frame 34.
2.
Unscrew the top fitting of the condensate
trap.
3.
Unscrew the fitting at the flue outlet drain
point.
4.
Unscrew the condensate outlet fitting.
5. Remove the two screws holding the white
retaining bracket and remove.
6. Replace condensate trap as required.
7.
Re-fit in reverse order.
8. Pour water into the heat exchanger to
ensure the condense trap is re-filled before
the unit is operated after servicing.
REPLACEMENT OF P
ARTS