IMAX XTRA EL
-
Installation & Servicing
66 NO CH BUT DHW OK
Set for Winter operation (see Frame 21)
no
Is the boiler set for Winter operation?
yes
Are the external controls calling for Heat?
Ensure that the Timer and Room
Thermostat are calling for heat
no
yes
Are the Radiator Valves open?
Open the Radiator Valves
no
yes
Is an OpenTherm device connected to the boiler (note
that the Ideal Prog Room Stat is an OpenTherm device)?
Does the wiring from the boiler to the
OpenTherm device have continuity?
yes
no
Rectify wiring from boiler
to OpenTherm device
no
Is there 230Vac at (A)?
There is no voltage from the external
controls. This is not a boiler fault.
Ensure voltage is supplied to the boiler
by correcting external wiring
no
yes
Is there 230Vac at (B)?
Check wiring from PCB to (B)
no
yes
yes
Does wiring to external CH Pump have continuity and is
wired to the correct connections?
Rectify wiring to external CH pump
no
yes
Is the CH pump stuck
Replace the CH pump
no
yes
Free the pump
0-10+
0-10-
DHW+
DHW-
OWC+
OWC-
OT+
OT-
PW
M
GND
INT
INT
LOCKOUT
LOCKOUT
BURNER ON
BURNER ON
N
L NO
L NC
N
L
L
N
LIVE OUT
CH CALL
LIVE OUT
DHW/CH2 CALL
HEAT
DEMAND
23
0v
50
Hz
MAINS
IN
230v
50Hz
DHW/
CH2
PUMP/
VALVE
CH/
BOI
LER
PUMP
VOLTS
FREE
CONTACTS
INTER/
LOCK
PUMP
CONTROL
0-10v
INPUT
TANK
SENSOR
OUTSI
DE
SENSOR
OPEN
THERM
switched
live
pump
control
0-10V
0 10
opentherm
master
- +
supply
All Mains Voltages are measured
between the test point and neutral
A
B