42
9. PowerVision™ software and interactive demo
A CD with the PowerVision™ Analysis Software and Interactive Demo has been included with the power
analyzer. This disk has an interactive demo to help the user get more familiar with the power analyzer
and PowerVision software.
The demo has an auto-run feature that will launch the interactive program immediately after it has been
inserted into the CD ROM drive. The program has four sections; an introductory section discussing the
features and benefits of the power analyzer, a display section that goes through the various display
screens and using the power analyzer as a portable hand-held analyzer, a programming section that
walks through some of the basic programming setup, and a software section that demonstrates the
capabilities of the PowerVision software.
The PowerVision software can be downloaded directly from this demo. It is complete with sample data,
allowing the user to try out the software and get a better understanding of what they can do with the data
before they take actual measurements.
10. Technical specifications
Supply voltage:
80-265VAC
Frequency:
50-60 Hz
Burden:
8 VA
Operation temperature: 0 to 50 ºC
Measuring circuit:
3
Φ
3-wire, 3
Φ
4-wire, 3PT-2CT, 1
Φ
, 1
Φ
Split
Safety:
Category III - 600 V, as per EN 61010
Internal memory:
1 MB
RS-232 output:
Serial type output
Baud rate:
1200, 2400, 4800, 9600, 19200, 38400 (user selectable)
Voltage measurement:
Measuring range:
20-500 VAC (phase-neutral)
20-866 VAC (phases-phase)
Frequency:
45-65 Hz
Current measurement:
Phase current range:
15-1000AAC*
Neutral current range: 1.5-100AAC**
Accuracy:
Voltage ..................................... 0.5 % of readout
±
2 digits
Current ..................................... 0.5 % of readout
±
2 digits
Active power ............................. 1.0 % of readout
±
2 digits
Reactive power.......................... 1.0 % of readout
±
2 digits
Measuring conditions to assure accuracy:
- Temperature range between 5 ºC and 45 ºC
- Power factor between 0.5 and 1
- Measuring range between 5 % and 100 %
* Based on supplied clamp adapter. Other clamp adapters available (Section 11)
** Catalog #61-807 supplied with 100AAC clamp adapter. Other clamp adapters available (Section 11)