3. Startup
The 800 series analyzers come standard with the Energy and Harmonics program loaded onto the
analyzer. Optional programs are available to expand the capabilities of your analyzer. More detailed
information about these programs is located in section 11 of this instruction manual.
3.1 Selecting a Program
SELECT PROGRAM
HARMONICS 7.02
EMPTY PROGRAM
EMPTY PROGRAM
EMPTY PROGRAM
LOAD PROGRAM
1) Press the red on button
<ON>
to power up the analyzer. This brings up the introductory screen of
the analyzer, where the user can select a program or load an additional program.
2) Use the up
[
5
]
and down
[
6
]
arrow keys to move cursor through the available programs listed in
the introductory screen. The cursor will automatically skip over the spaces that are currently empty
and reserved for optional programs.
3) To select the Energy and Harmonics program, select HARMONICS and press the enter key
[ENTER]
.
4) If no program is selected after a few seconds, the analyzer will automatically select the program
highlighted by the cursor.
3.2 Loading a new program
The 800 series analyzer can hold up to 4 programs at one time. Optional programs can be loaded onto
any of the available spaces on the analyzer, which are labeled as EMPTY PROGRAM on the introductory
screen. The programs come loaded onto a cartridge and are downloaded onto the analyzer through the
power supply/RS-232 interface.
To load a new program:
1) Turn the analyzer off
2) Plug the power cord into the power supply/RS-232 interface. The analyzer must have line power
throughout the program loading process.
3) Connect the analyzer to the power supply/RS-232 interface with the interface cable.
4) Insert the cartridge loader into the small auxiliary input on the front of the power supply/RS-232
interface.
Note: A cartridge program loader can be used on only one individual
analyzer. The download of the program includes an identification step,
which prohibits the download of the optional program to other
analyzers. The program can be reloaded onto the original analyzer an
unlimited number of times. Remember to write the serial number of
your power analyzer on the cartridge loader.