Installation & Servicing
GENERAL
2 FLOOR MOUNTING AND BOILER CLEARANCES
Flammable materials must not be placed in close proximity
to the appliance. Materials giving off flammable vapours
must not be stored in the same room as the appliance.
Floor mounting
1.
The floor must be flat, level and of suitable load bearing
capacity.
2.
The back of the boiler may be fitted up to the wall.
Boiler clearances
The minimum overall dimensions of the space in which the
boiler is to operate and to facilitate servicing are as follows:-
Dimension
A
RS485 & 4100
10 mm (
3/8
")
RS4125
55 mm (2
1/4
")
1.
This appliance is NOT suitable for use in a
direct hot water system.
2.
If the boiler is to be used on a sealed system,
an
Overheat Thermostat Kit
is available and
must be installed in accordance with the
instructions supplied with the kit.
1 BOILER WATER CONNECTIONS
Additional space will be required for installation, depending
upon site conditions.
IMPORTANT.
In order to facilitate gas connection, a clearance of at least 100
mm (4") must be available at either the left hand side or the right
hand side DURING installation. Refer to Frame 10.
In addition a MINIMUM clearance of 533 mm (21") MUST be
available at the front of the boiler, for servicing.
Boiler Size
Width
Depth
Height
RS485 &
RS4100
mm (in.)
460 (18)
533 (21)
870 (34
1/4
)
RS4125
mm (in.) 550 (21
1/2)
600 (23
5/8
) 870 (34
1/4
)
Dimension
A
B
RS485 &
299mm (11
3/4
")
533 (21")
RS4100
RS4125
373 mm (14
5/8
")
600 (23
5/8
")
Terminal sizes
Boiler Size
Depth
Height
Width
RS485
167
392
372
RS4100 & 4125
182
431
372