3
Mexico Super RS485 - RS4125 -
Installation & Servicing
GENERAL
NOTE TO THE INSTALLER: LEAVE THESE
INSTRUCTIONS ADJACENT TO THE GAS METER.
ALSO COMPLETE THE BENCHMARK LOG BOOK
AND GIVE THIS TO THE CUSTOMER.
CONTENTS
Air Supply
. ......................................................................
6
Boiler Assembly - Exploded view
...............................
11
Boiler Clearances
..........................................................
5
Burner Assembly - Exploded view
.............................
35
Electrical Connections
................................................
16
Electrical Diagram
.......................................................
17
Electrical Supply
............................................................
7
Fault Finding
.................................................................
30
Flue Fitting
....................................................................
15
Flue Installation
..............................................................
6
Gas Safety Regulations
.................................................
4
Gas Supply
.....................................................................
6
Initial Lighting
...............................................................
21
Installation
...................................................................
11
Mandatory Requirements
.............................................
4
Pump
..............................................................................
8
Servicing
......................................................................
23
Short List of Parts
.......................................................
31
System Diagrams
(Electrical)
.....................................
18
Terminal Guards
. ...........................................................
6
Terminal Sizes
. ............................................................
14
Water Connections
..............................................
5 & 16
Water Systems
..............................................................
8
Mexico Super RS
B.G. Certified - P.I. No. 87AT14
Destination Countries: GB & IE
Appliance type: C
11
Models
G.C. Appliance No.
Mexico Super RS485 ..................... 41 392 78
Mexico Super RS4100 ................... 41 392 79
Mexico Super RS4125 ................... 41 392 80
Natural Gas only
BENCHMARK LOG BOOK DETAILS
B
oiler
Page
Make and model ....................................................... 3
Appliance serial no. on data badge ........................ 11
SEDBUK No. % ......................................................... 2
Controls
Time and temperature control to heating ......... 18/19
Time and temperature control to hot water ...... 18/19
Heating zone valves .......................................... 18/19
TRV's ......................................................................... 7
Auto bypass ............................................................... 7
Boiler interlock .......................................................... 7
For all boilers
Flushing to BS.7593 .............................................. 16
Inhibitor ................................................................... 16
Central heating mode
Heat input ................................................. to be calculated
For assistance see Technical Helpline on the back page
Page
Burner operator pressure ......... measure and record
Central heating flow temp. ........ measure and record
Central heating return temp. ..... measure and record
For combination boilers only
Scale reducer ......................................................... n/a
Hot water mode
Heat input ............................................................... n/a
Max. operator burner pressure ..............................n/a
Max. operating water pressure ..............................n/a
Cold water inlet temp ............................................. n/a
Hot water outlet temp. ............................................n/a
Water flow rate at max. setting ...............................n/a
For condensing boilers only
Condensate drain ..................................................n/a
For all boilers:
complete, sign & hand over to customer
For GB, to comply with Building Regulations Part L1 (Part J in Scotland) the boiler should be fitted in accordance with the
manufacturer's instructions. Self-certification that the boiler has been installed to comply with Building Regulations can be
demonstrated by completing and signing the Benchmark log book.
INTRODUCTION
Mexico Super RS
above range
is of floor standing, natural
draught, balanced flue gas boilers. They are rated to provide
central heating outputs of 24.9 kW (85,000 Btu/h) to 36.6 kW
(125,000 Btu/h).
The boiler has a cast iron heat exchanger and is supplied fully
assembled, complete with a white enamelled mild steel
casing.
A door at the top of the casing front panel hinges down,
revealing the boiler thermostat control (and programmer, if
fitted).
The boilers are suitable, as standard, for connection to open-
vented systems ONLY - an overheat thermostat kit is available
to allow the boiler to be used on sealed water systems.
The systems may be:
•
pumped or gravity circulating indirect DHW only
•
pumped central heating only
•
pumped central heating combined with either a pumped or
gravity circulating indirect DHW circuit.
200942-1.p65
3/4/2004, 9:24 AM
3