4
icos system condensing -
Installation and Servicing
GENERAL
1
BOILER WATER CIRCUIT DIAGRAM
INTRODUCTION
The icos system m3080
boiler is a fully automatically
controlled wall mounted, low water content, fanned flue
condensing gas boiler.
Note.
Due to the high efficiency of the boiler a plume of water
vapour will form at the terminal during operation.
The output is fully modulating with a range of:
8.8 to 23.4kW (30,000 to 80,000 Btu/h)
The boiler is supplied fully assembled with circulating pump,
pressure gauge, safety valve and expansion vessel.
Variable temperature control is fitted on the user control.
The boiler casing is of white painted zintec coated mild steel.
The boiler temperature controls are visible at the bottom RHS
of the front panel.
The heat exchanger is of aluminium.
The boiler is suitable for connection to fully pumped, sealed
water systems ONLY.
The system pipework MUST include drain cocks in appropriate
places.
Pipework from the boiler is routed downwards as standard, but
may be routed upwards behind the boiler using the stand-off
frame (supplied in a separate kit).
Expansion
vessel
Automatic
air vent
Heat
engine
Gas valve
Pump
Safety
relief valve
Condensate
's' trap
Water
pressure
gauge
Sump
Fan
Burner
Flo
w
Gas
Condensate dr
ain
Discharge pipe
Ecl 2063
Retur
n
OPERATION
When there is a demand for heat, the heating system is
supplied at the selected temperature of between 42
o
C and
82
o
C.
Refer also to Frame 1 - 'Boiler Water Circuit Diagrams'
The boiler features a comprehensive diagnostic system which
gives detailed information on the boiler status when operating,
and performance of key components to aid commissioning and
fault finding.
OPTIONAL EXTRA KITS
z
Flue Extension Ducts
Pack D up to 3m (122in).
z
Flue Elbow Kit
90 degree pack.
z
Flue Elbow Kit
45 degree pack (2 per pack).
z
Powered Vertical Flue Kit (to
a maximum primary flue
length of 4m + a maximum secondary flue length of 5m)
z
Roof Flue Kit
(to a maximum of 5m)
z
Remote User Controls Kit
z
Boiler Stand-off Kit
z
Siphon Kit
z
Concealment Panel Kit
z
Flue Finishing Kit