18
icos system condensing -
Installation and Servicing
INSTALLATION
FLUE OUTLET
1.
A
maximum
of 3 extension ducts (one suitably
cut) plus the standard flue duct may be used
together.
2.
Flue extensions of greater length than 1m (39")
should be supported with the bracket provided,
suitably adjusted - refer to Frame 21.
22 FLUE EXTENSION DUCTS - continued
1.
Remove the cardboard support aid from the flue and
place safely to one side.
2.
Fit the inner flue extension duct onto the inner flue duct.
3.
Fit the outer flue extension duct onto the outer air duct.
4.
Using the clamp provided clamp the flue lengths
together.
5.
Repeat steps 1-4 if a second flue extension is required.
6.
Measure and mark the flue length required onto the flue,
measuring from the groove near the terminal.
7.
To ensure a square cut, mark the flue all the way round.
8.
Cut to length using the cardboard support aid.
9.
Remove the cardboard off-cut and deburr the metal
edges.
23 FITTING THE KIT
21 FLUE EXTENSION DUCTS - For flue lengths greater than 480mm
Pack D Flue extension duct kit contents.
Note.
Side flue shown
General arrangement
20 TERMINAL WALL PLATE (optional)
This plate is supplied in the Flue Finishing Kit (together with
one inner and one outer flue seal) it allows neat concealment
and full compression of the outer seal (if fitted). Its use is not
essential if the flue hole and flue ducts have been accurately
cut and the outside wall face is flat.
1.
Position the terminal wall plate over the terminal.
2.
Drill 4 fixing holes with a 7mm (1/4") masonry drill.
3.
Insert the 4 plastic plugs provided.
4.
Secure the plate with 4 of the No.10 x 2" screws provided.
Note.
If the terminal is less than 2m (6' 6") above ground
level, an approved terminal guard should be fitted. Refer to
the Flue Installation, Page 8.
Flue duct support
Flue support cutting aid
(shown folded up)
Wall plugs - 4 off
Extension duct & clamp
1.0m (39") long
No. 10 x2" wood screw - 4 off
Ecl 1244
Ecl 1531
Boiler
Standard flue
Terminal grille
Flue length
Extension flue
GROOVE
2
3
9
Ecl 1532
Use a maximum of 3m extended flue ONLY
FLUE OUTLET