14
icos system condensing -
Installation and Servicing
INSTALLATION
2009
2
1
3
4
5
Note.
The template shows the positions of the fixing holes and
the flue hole centres for standard installation and for using
the stand-off. Care Must be taken to ensue the correct
holes are drilled.
1.
Tape template into the selected position.
2.
Ensure squareness by hanging a plumbline as shown. If
fitting a side flue extend the flue centre line onto the side
wall.
3.
Mark onto the wall the following:
a
The piping frame screw positions (choose one from
each group).
b.
The position of the flue duct hole.
Note.
Mark the centre of the hole as well as the
circumference
4.
Remove the template from the wall.
13 WALL MOUNTING TEMPLATE
12 FLUE ASSEMBLY - Exploded View
LEGEND
1.
Duct assembly.
2.
Flue Turret.
3.
Turret seal.
4.
M5 x 10 pozi screw.
5.
Turret clamp.
1.
An optional flue duct extension kit is required
for wall thicknesses greater than :
Side
300mm (11
3/4
").
Rear
345mm (13
1/2
").
Rear flue arrangement shown
Note.
Side flue only. If the system pipework is to be routed
up behind the boiler. The upward routing pipework
frame supplied as a separate kit MUST be used
secured to the piping frame. It is essential to use the
wall mounting template to mark the holes to be
drilled. Care MUST be taken to ensure the correct
holes are drilled.
V
2010
See wall mounting plate
18
31
44
57
70
83
2035
INST