29
Buccaneer GTE -
Installation & Servicing
GENERAL
COMBINATION BOILERS
buc5536
INTRODUCTION
The Buccaneer GTE Combination Boilers are automatic
independent hot-water boilers designed for connecting to a flue
which require a separate fuel oil or gas burner.
Models available:
•
Heating and domestic hot water:
- Buccaneer GTE Combination Boiler - Boiler with an MLS
160 or 250 litre domestic hot water tank and a standard
control panel.
•
The DHW calorifier is equipped with a titanium anode. This
system is controlled by the control panel and ensures the
calorifier needs no maintenance.
Important Recommendations
•
The boiler/tank assembly must be installed in premises free
from frost. Placing the tank as closely as possible to the
water supply will minimise energy losses in the pipework
which should be lagged in all cases.
•
It is advisable to place the boiler/tank assembly on a plinth
so that the area can be easily cleaned.
Description
The tank, made of high-grade steel, is lined on the inside with
vitrified enamel which protects the tank from corrosion.
The tank is also protected from corrosion by a titanium anode.
The heat exchanger fitted in the tank is constructed of smooth
tubing. Those surfaces coming into contact with domestic hot
water are enamelled.
The tanks are heavily insulated in CFC-free polyurethane foam,
thus reducing heat losses to a minimum.
The outer casing is in painted sheet metal.
WARNINGS.
-
Installation, commissioning and maintenance must be
carried out by a qualified technician, in accordance with
installation practices and the instructions in this document.
-
Regular maintenance of the equipment is necessary to
ensure safe and reliable performance.
-
For the guarantee to remain valid, no modifications must be
made to the domestic hot water tank.
-
Central heating water and domestic hot water must never
come into contact. In particular, the exchanger must not
circulate domestic hot water.
Boiler
GTE 4/160
GTE 5/160
GTE 5/250
GTE 6/160
GTE 6/250
Net weight
kg
264
289
352
315
379
Domestic hot water production
Tank capacity
litres
160
160
250
160
250
Continuous flow (2) (4)
litres/h
665
690
810
885
885
Specific flow** according to EN 303-6 (3) (4)
litres/min.
20.5
20.5
30
20.5
30
Drawing capacity (in 10 min.) *** (3) (4) litres/10min.
255
255
385
255
385
Table 2 Technical Data
(2)
Exchanger inlet temperature at 80
o
C
Domestic hot water temperature at 45
o
C
(3)
Domestic (temperature) set to 60
o
C
Domestic hot water average temperature at 40
o
C
Boiler (temperature) set to 80
o
C
(4)
Cold water temperature at 10
o
C
Pump in position 3
** Specific flow: domestic hot water flow corresponding to a
minimal increase in average temperature of 30K which the
appliance can provide during two successive draws of 10
minutes separated by a stoppage of 20 minutes.
*** Drawing capacity in 10 minutes: hot water flow for which
water can be drawn for a period of 10 minutes with an average
increase in temperature of 30K.
Condition for flow: water at 10
o
C in the boiler.